Operating status

(Steam Commercial only)
When starting the steam generator, a connection/voltage is
output on the terminal "S,S" depending on the connection option
selected (A or B). It is used to indicate to other equipment that
the steam generator is in operation. Note: An RJ10 adapter is
required for the function to work (connected to pos. 4 (SEC/NTC)
on the relay board).
A
Internal
PCB
S S
(0V signal)
Pin:
1
2 3 4
4
1
2
3
5
6
7
8
Figure 40 Operating status connection
B
Internal
PCB
S S
V-in/out max 240V 10A
1
2
3
4
9

Multisteam

Note: Only the Elite control panel can be used for Multisteam.
When the steam generator capacity is not sufficient for the steam-
room volume, multiple steam generators need to be connected
together to increase the power demand. A maximum of 3 Steam
Commercial units can be connected together. See the section,
"Correct power output in relation to room volume".
Multisteam also provides the advantage that steam production
does not cease completely during the automatic draining during
operation, because at least one steam generator is always produ-
cing steam.
With Multisteam, each individual steam generator must be con-
nected with electricity, water, drainage and steam piping.
The connection of the control panel, temperature sensor, external
switch, door contact, synchronisation cable and additional equip-
ment is always made to the primary unit. Secondary units only
support synchronisation cable RJ10 pos. 6-9.
When more than one generator is connected together, one of
them is set up to be the "Primary" (factory setting) and is the one
which controls the other generators. The other units are then set
up to be "Secondary" using the dipswitch, see Figure 43.
The connections between the generators use a low power cable
(2 core, RJ10 2P4C A/B)) with an RJ10 connector, (Figure 43)
See the section "Description of cabling/modular contacts" (Figure
44) for more information on the pin configuration.

Tylarium

Note: Only the Elite control panel can be used for Tylarium.
Tylarium is a system consisting of a sauna heater connected with
a Commercial or Home steam generator. Note: This system is not
used in a steamroom but in a sauna room. For more information,
read the instructions for Tylarium.