Download Inhoudsopgave Inhoud Print deze pagina

General Information; Installation Requirements; Installation Planning - Tylo STEAM HOME Installatie- En Gebruikershandleiding

Inhoudsopgave

Advertenties

T
he steam piping must not have any sharp bends.
D
o not direct the steam jet against walls, seats or other
A
objects.
lways keep a space of at least 80 cm clear in front
of the steam nozzle.
T
here must not be any water pockets in the steam piping
IMPORTANT! T
or ventilation ducts.
be any kind of blockage in the steam piping (e.g. taps or
T
valves).
he internal diameter of the steam piping must not
be reduced.
A
ll steam rooms in continuous use for more than two hours
must have an air exchange rate of 10-20 m³ air per person
per hour.
T
he power supply for the steam generator must not be cut
T
off.
herefore avoid installing a power switch, etc. in the
power supply line.
T
he drain pipe must have a continuous fall all the way from
the steam generator to the drain.
T
he ambient temperature for the steam room and steam
generator must not exceed 35°C.
T
he sensor must be located as far from the steam jet as
possible.
D
escale the steam generator regularly in accordance with

Installation requirements

WARNING! Electrical wiring must be performed
by a qualified electrician pursuant to applicable
regulations.
WARNING! The water and pipework installation
must be performed by a qualified plumber
pursuant to applicable regulations.
IMPORTANT!
the instructions, refer to the heading "Descaling".
water, exceeding 4°dH hardness, a water softener or Tylö MACH
2020 water softener must be installed (Tylö Item no. 9090 8025)
C
lean the steam room regularly
NB! T
channel outside the steam room.
here must not
tank 1 hour after each bath, the water will then be 80-85°C!.
WARNING! T
N
ever leave small children unattended.
T
his appliance can be used by children aged from 3 years and
above and persons with reduced physical, sensory or mental capa-
bilities or lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe
way and understand the hazards involved.
C
hildren shall not play with the appliance.
C
leaning and user maintenance shall not be made by children
without supervision.
C
hildren aged from 3 to 8 years are only allowed to operate the tap
connected to the water heater.
T
he incoming water pressure must be between min. 0.2 and max 10
bar (min. 20kPa and max 1000kPa).
M
eans for disconnection must be incorporated in the fixed wiring in
accordance with the wiring rules.

General information

Installation planning

Before starting to install your steam generator, you should consi-
der:
he steam generator drain must always lead to a drainage
here is a jet of hot steam from the steam nozzle.
Location of steam generator – see Figures 3, 4, 5
Electrical installation – see Figures 26-36, 37
Water connection and drain – see Figures 10, 14
Steam pipe – see the "Steam pipe connection" section and
Figures 17-20
Steam nozzle – see the "Steam nozzle" section and Figures
21-25
Steamroom ventilation – see the Ventilation section
Location of temperature sensor – see the "Location of
temperature sensor" section and Figure 37
I
n areas with hard
T
he steam generator empties its
33

Advertenties