Download Inhoudsopgave Inhoud Print deze pagina

Pipework Installation - Tylo STEAM HOME Installatie- En Gebruikershandleiding

Inhoudsopgave

Advertenties

38
To be done by an authorised plumber.
K
Figure 10 Pipework installation diagram
A. Steam pipe - should be insulated if longer than 3 metres
B. Drain piping
C. Safety valve piping (0.5 bar)
D. Motorised ball valve (included with the steam generator)
E. Motorised ball valve pipe adapter (included with the steam generator)
F. Water piping
G. Non-return valve (included with the steam generator)
H. Reinforced rubber hose for steam generator water connection
I. Shut-off valve for incoming water
J. Steam Home/Steam Commercial
K. Supply air into the steamroom under the door
L. The outlet vent must be connected to a ventilation duct that conducts the air outdoors (see the Ventilation section)

Pipework installation

L
A
J
E
D
C
B
I
F
G
H