Necessary Tools for Installation
●Driver
●Nipper
●Hacksaw
●Hole core drill
●Spanner(17,19 and 26mm)
●Gas leakage detector or
soap-and-water solution
Selection of Installation Place
●Place, robust not causing vibration, where the body can be
supported sufÏciently.
●Place, not affected by heat or steam generated in the vicinity,
where inlet and outlet of the unit are not disturbed.
●Place, possible to drain easily, where piping can be connected
with the outdoor unit.
●Place, where cold air can be spread in a room entirely.
●Place, nearby a power receptacle, with enough space around.
●Place where the distance of more than 1m from televisions,
radios, wireless apparatuses and fluorescent lamps can be left.
●In the case of fixing the remote controller on a wall, place where
the indoor unit can receive signals when the fluorescent lamps in
the room are lightened.
The models adopt HFC refrigerant R32.
more than 15 cm
more than
10cm
The distance between the indoor unit and the floor should be more than 2m.
Please be subject to the actual product purchased, the above picture is just for your reference.
If using the left side drain pipe, make sure the hole is got through.
Indoor Unit Installation
●Torque wrench ( 17mm,
22mm, 26mm )
●Pipe cutter
●Flaring tool
●Knife
●Measuring tape
●Reamer
Drawing for the installation of indoor units
more than 10cm
Power Source
●Before inserting power into receptacle, check the voltage without
fail.
●The power supply is the same as the corresponding nameplate.
●Install an exclusive branch circuit of the power.
●A receptacle shall be set up in a distance where the power cable
can be reached. Do not extend the cable by cutting it.
Attention must be paid
to the rising up of drain
hose.
Arrangement of piping
directions.
Rear left
Left
Rear
right
Right
EN
10