Parameterlijsten
4.1.23 32-** MCO basisinstell
Par.
Parameterbeschrijving
Nr. #
32-0* Encoder 2
32-00
Incrementeel signaaltype
32-01
Incrementele resolutie
32-02
Absoluut protocol
32-03
Absolute resolutie
32-04
Absolute Encoder Baudrate X55
32-05
Datalengte absolute encoder
32-06
Klokfrequentie absolute encoder
32-07
Klokgeneratie absolute encoder
32-08
Kabellengte absolute encoder
32-09
Encoderbewaking
32-10
Draairichting
32-11
Deler eenheid gebr.
32-12
Noemer eenheid gebr.
32-13
Enc.2 Control
32-14
Enc.2 node ID
32-15
Enc.2 CAN guard
32-3* Encoder 1
32-30
Incrementeel signaaltype
32-31
Incrementele resolutie
32-32
Absoluut protocol
32-33
Absolute resolutie
32-35
Datalengte absolute encoder
32-36
Klokfrequentie absolute encoder
32-37
Klokgeneratie absolute encoder
32-38
Kabellengte absolute encoder
32-39
Encoderbewaking
32-40
Encoderafsluiting
32-43
Enc.1 Control
32-44
Enc.1 node ID
32-45
Enc.1 CAN guard
32-5* Terugk.bron
32-50
Bron slave
32-51
MCO 302 slotactie
32-52
Source Master
32-6* PID-regelaar
32-60
Proportionele factor
32-61
Afleidingsfactor
32-62
Integrale factor
32-63
Grenswaarde voor integr. som
32-64
PID-bandbreedte
32-65
Snelheid voorwaartse koppeling
32-66
Versn. voorwaartse koppeling
32-67
Max. toegestane positiefout
32-68
Omgekeerd gedrag voor slave
32-69
Samplingtijd voor PID-regeling
32-70
Scantijd voor profielgenerator
32-71
Grootte van Control Window (insch.)
32-72
Grootte van Control Window (uitsch.)
32-73
Integral limit filter time
32-74
Position error filter time
32-8* Snelh. & versn.
32-80
Max. snelheid (encoder)
32-81
Kortste ramp
32-82
Type ramp
32-83
Snelheidsresolutie
32-84
Standaard snelheid
32-85
Standaard versn.
32-86
Acc. up for limited jerk
32-87
Acc. down for limited jerk
32-88
Dec. up for limited jerk
MG33MH10
Programmeerhandleiding
Standaardwaarde
[1] RS422 (5V TTL)
1024 N/A
[0] Geen
8192 N/A
[4] 9600
25 N/A
262 kHz
[1] Aan
0 m
[0] Uit
[1] Geen actie
1 N/A
1 N/A
[0] No soft changing
127 N/A
[0] Uit
[1] RS422 (5V TTL)
1024 N/A
[0] Geen
8192 N/A
25 N/A
262 kHz
[1] Aan
0 m
[0] Uit
[1] Aan
[0] No soft changing
127 N/A
[0] Uit
[2] Encoder 2
[1] Uitsch.
[1] Encoder 1 X56
30 N/A
0 N/A
0 N/A
1000 N/A
1000 N/A
0 N/A
0 N/A
20000 N/A
[0] Omkeren toegestaan
1 ms
1 ms
0 N/A
0 N/A
0 ms
0 ms
1500 RPM
1 s
[0] Lineair
100 N/A
50 N/A
50 N/A
100 ms
0 ms
0 ms
Danfoss A/S © Rev. 2014-01-30 Alle rechten voorbehouden.
4-set-up
Wijzigen
Conver-
tijdens
sie-index
bedrijf
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
All set-ups
FALSE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
Type
-
Uint8
0
Uint32
-
Uint8
0
Uint32
4
4
-
Uint8
0
Uint8
0
Uint32
-
Uint8
0
Uint16
-
Uint8
-
Uint8
0
Uint32
0
Uint32
-
Uint8
0
Uint8
-
Uint8
-
Uint8
0
Uint32
-
Uint8
0
Uint32
0
Uint8
0
Uint32
-
Uint8
0
Uint16
-
Uint8
-
Uint8
-
Uint8
0
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Uint32
0
Uint32
0
Uint32
0
Uint16
0
Uint16
0
Uint32
0
Uint32
0
Uint32
-
Uint8
-3
Uint16
-3
Uint8
0
Uint32
0
Uint32
-3
Int16
-3
Int16
67
Uint32
-3
Uint32
-
Uint8
0
Uint32
0
Uint32
0
Uint32
-3
Uint32
-3
Uint32
-3
Uint32
211