5.5. Fault: Drilling core stuck in the diamond core drilling crown.
Cause:
● Compressed drilling dust, parts of the drilling core jammed in the drilling
tube.
5.6. Fault: Diamond core drilling crown is difficult to release from the drive spindle.
Cause:
● Dirt, corrosion.
5.7. Fault: Diamond core drilling crown does not work.
Cause:
● PRCD fault current circuit breaker (19) is not switched on.
● Worn carbon brushes.
● Mains lead/PRCD defective.
● Diamond core drilling machine defective.
6. Disposal
The electric diamond core drilling machines may not be thrown into the domestic
waste at the end of use. They must be disposed of properly by law.
7. Manufacturer's Warranty
The warranty period shall be 12 months from delivery of the new product to the
first user. The date of delivery shall be documented by the submission of the
original purchase documents, which must include the date of purchase and the
designation of the product. All functional defects occurring within the warranty
period, which are clearly the consequence of defects in production or materials,
will be remedied free of charge. The remedy of defects shall not extend or
renew the warranty period for the product. Damage attributable to natural wear
and tear, incorrect treatment or misuse, failure to observe the operational
instructions, unsuitable operating materials, excessive demand, use for unau-
thorized purposes, interventions by the customer or a third party or other
reasons, for which REMS is not responsible, shall be excluded from the warranty
Services under the warranty may only be provided by customer service stations
authorized for this purpose by REMS. Complaints will only be accepted if the
product is returned to a customer service station authorized by REMS without
prior interference in an unassembled condition. Replaced products and parts
shall become the property of REMS.
The user shall be responsible for the cost of shipping and returning the product.
The legal rights of the user, in particular the right to make claims against the
seller under the warranty terms, shall not be affected. This manufacturer's
warranty only applies for new products which are purchased in the European
Union, in Norway or in Switzerland.
This warranty is subject to German law with the exclusion of the United Nations
Convention on Contracts for the International Sales of Goods (CISG).

8. Spare parts lists

For spare parts lists, see www.rems.de → Downloads → Parts lists.
24
Remedy:
● Unscrew the diamond core drilling crown from the drive unit, knock out the
drilling core with a rod, do not damage the connecting thread. Never hit the
jacket of the drilling tube with metal parts (e.g. hammer, wrench). This will dent
the drilling tube inwards and aggravate the risk of the drilling core jamming in
future. The diamond core drilling crown could then be rendered useless. Use a
dust extractor for drilling, see 2.4.2 or drill wet.
Remedy:
● Clean the thread of the drive spindle and the diamond core drilling crown and
oil lightly.
Remedy:
● Switch on PRCD fault current circuit breaker as described in 2.1.
● Have the carbon brushes changed by qualified personnel or an authorised
REMS customer service workshop.
● Have the mains lead/PRCD replaced by qualified personnel or an authorised
REMS customer service workshop.
● Have the diamond core drilling machine checked/repaired by an authorised
REMS customer service workshop.
eng

Advertenties

Inhoudsopgave
loading

Gerelateerde Producten voor REMS Picus S1

Deze handleiding is ook geschikt voor:

Picus s3Picus s2/3.5Picus srTitanSimplex 2

Inhoudsopgave