Installatie
4
Information regarding UL
4.4.5
Ambient temperature
4.4.6
Environmental Conditions
84
Technische handleiding – MOVIDRIVE
The units are suitable for an ambient temperature of 40 °C, max. 60 °C with derated
output current.
To determine output current rating at higher than 40 °C, the output current should be
derated 2.5 % per °C between 40 °C and 50 °C, and 3 % per °C between 50 °C and
60 °C.
AANWIJZING
- Use only tested units with a
output current (I
= 8 A) as an external DC 24 V voltage source.
max
- UL certification does not apply to operation in voltage supply systems with a non-
grounded star point (IT systems).
The units are for use in pollution degree 2 environments.
®
MDX60B/61B
limited output voltage
(V
= DC 30 V) and
limited
max