8
Gas burner
Check if the burner opening is clear of pollution. Checks circuit and connections
on leaks and external damages.
All maintenance or service activities may only been
carried out by a recognized service technician. Do not
manipulate the gas components as an end user!
Ignition transformer burner:
It is important that on the ignition transformer a load is connected.
The switching on of the ignition transformer without the ignition pins are
connected, are not permitted. We recommend during maintenance activities
certainly checking the connections of the ignition cables and for the case the
burner would not work, certainly don't run the burner.
Working activities to the ignition transformer can/may be done only
when no gas supply is possible! Always ensure sufficient ventilation!
9
Water tank
Check the water tank on external damages and leaks.
Check when the tank is filling if the float system works properly.
10
CNG tanks
Check on damages, corrosion or leaks (visual detection & odor detection) & let
replace/repair the tank at negative remarks/observations. If damaged or at any
leaks they must be replaced immediately by an authorized installer.
Check the quick release swivel bolt band clamps for tightness with desired
tightening torque; 30 Nm. Check between tank and brackets for the presence
of the insulating material (rubber).
Check on the presence of the shielding (necessary for keeping the filling
connection clean and preventing dirt in the system) of the filling connection.
Also check that the burst disc of the electromechanical valve is provided
with the plastic seal (see photo). If not present: valve must be replaced by a
recognized installer! A thorough (re)check of the gas module is also required if
the following situations occur, for example:
• Gas air
• Unexplained pressure loss in the gas system
• Indications of loose parts and unusual noises
• Exceeding the permitted operating pressure
• Serious modifications to the gas system
• Dismantling or relocation of the gas module
11
Battery
Check the battery on good connections / possible wear and whether the battery
needs to be recharged. See also: "32 battery" on page 27 .
Pull out the service switch (orange plug) at all times if
the battery requires/demands service. Service on the
battery may only be carried out by authorized, qualified
(DiBO) technicians or you have to contact DiBO!
Caution: Ventilate sufficiently when reloading the battery.
Ensure that the gas tanks are empty before recharging!
Avoid risk of sparks (no smoking). Ensure a good electrical
connection of the charger with the battery!
12
Diaphragm pump and filter
Clean the diaphragm pump valves regularly. Also clean the filter sieve regularly
inside the filter of the cooling circuit.
DiBO 45
E N
S E R V I C E