Naam
Par.
Omschakelbare par.
Parameterset 1/2
420
Hysteresis
421
Delay time
422
Signal = "1" if:
43_
Current reference message
430
Current reference value
431
Hysteresis
432
Delay time
433
Signal = "1" if:
44_
Imax signal
440
Hysteresis
441
Delay time
442
Signal = "1" if:
5__
MONITORING FUNCTIONS
50_
Speed monitoring
500 / 502 Speed monitoring 1/2
501 / 503 Delay time 1 / 2
504
Encoder monitoring motor
505
Synchronous encoder monitoring
51_
Synchr. operation monitoring
510
Positional tolerance slave
511
Prewarning lag error
512
Setpoint deviation limit
513
Lag error delay message
514
Counter LED display
515
Delay in-position signal
516
X41 Encoder monitoring
517
X41 Pulse count monitoring
518
X42 Encoder monitoring
519
X42 Pulse count monitoring
52_
Mains OFF monitoring
520
Mains OFF response time
521
Mains OFF response
522
Phase failure monitoring
53_
Motor temperature protection
530
Sensor type 1
531
Sensor type 2
Technische handleiding – Applicatieregelaar MOVIDRIVE
Complete parameterlijst
Instelbereik
Fabrieksinstelling
0 ... 100 ... 300 1/min
0 ... 1 ... 9 s
n Á n
setp
n = n
setp
0 ... 100 ... 200 % I
N
0 ... 5 ... 30 % I
N
0 ... 1 ... 9 s
I < I
ref
I > I
ref
0 ... 5 ... 50 % I
N
0 ... 1 ... 9 s
I = I
/ I < I
max
max
OFF
MOTOR MODE
REGENERAT. MODE
MOT. & REGEN.MODE
0 ... 1 ... 10 s
No
Yes
No
Yes
10 ... 25 ... 32 768 inc.
50 ... 99 999 999 inc.
100 ... 4000 ... 99 999 999 inc.
0 ... 1 ... 99 s
10 ... 100 ... 32 768 inc.
5 ... 10 ... 2000 ms
YES
NO
YES
NO
YES
NO
YES
NO
0 ... 5 s
CONTROLLER INHIBIT
EMERGENCY STOP
ON
Off
No sensor
TF/TH/KTY (KTY: alleen voor DS/CM-moto-
ren)
No sensor
TF/TH/KTY (KTY: alleen voor DS/CM-moto-
ren)
®
MDX60B/61B
Inbedrijfstelling
Opmerking
I
6
0 0
99