Inbedrijfstelling
I
6
Complete parameterlijst
0 0
Naam
Par.
Omschakelbare par.
Parameterset 1/2
1__
SETPOINTS/RAMP GENERATORS
10_
Setpoint selection
\100
Setpoint source
101
Control signal source
102
Frequency scaling
11_
Analog input AI1
110
AI1-scaling
111
AI1 Offset
112
AI1 operating mode
113
AI1 voltage offset
114
AI1 speed offset
115
Filter speed setpoint
12_
Analog inputs (optional)
120
AI2 operating mode
13_
Speed ramps 1
\130
Ramp t11 up CW
\131
Ramp t11 down CW
\132
Ramp t11 up CCW
\133
Ramp t11 down CCW
\134
Ramp t12 UP=DOWN
135
S pattern t12
\136
Stop ramp t13
\137
Emergency stop ramp t14
138
Ramp limit VFC
139
Ramp monitoring 1
14_
Speed ramps 2
140
Ramp t21 up CW
141
Ramp t21 down CW
142
Ramp t21 up CCW
143
Ramp t21 down CCW
144
Ramp t22 UP=DOWN
145
S pattern t22
146
Stop ramp t23
147
Emergency stop ramp t24
149
Ramp monitoring 2
15_
Motor potentiometer (parametersets 1 and 2)
150
Ramp t3 up
151
Ramp t3 down
Save last
152
setpoint
16_
Fixed setpoints 1
\160
Internal setpoint n11
\161
Internal setpoint n12
\162
Internal setpoint n13
17_
Fixed setpoints 2
170
Internal setpoint n21
171
Internal setpoint n22
172
Internal setpoint n23
96
Instelbereik
Fabrieksinstelling
UNIPOL/FIX.SETPT
TERMINALS
0,1 .. 10 ... 65 kHz
–10 ... –0,1 / 0,1 ... 1 ...10
–500 ... 0 ...500 mV
Ref. N-MAX
–10 ... 0 ... 10 V
–6000 ... 0 ... 6000 1/min
0 ... 5 ...100 ms
0 = filter uit
NO FUNCTION
0 ... 2 ... 2000 s
0 ... 2 ... 2000 s
0 ... 2 ... 2000 s
0 ... 2 ... 2000 s
0 ... 10 ... 2000 s
0 ... 3
0 ... 2 ... 20 s
0 ... 2 ... 20 s
Yes
No
Yes
No
0 ... 2 ... 2000 s
0 ... 2 ... 2000 s
0 ... 2 ... 2000 s
0 ... 2 ... 2000 s
0 ... 10... 2000 s
0 ... 3
0 ... 2 ... 20 s
0 ... 2 ... 20 s
No
Yes
0,2 ... 20 ... 50 s
0,2 ... 20 ... 50 s
OFF
ON
–6000 ... 150 ... 6000 1/min (% I
–6000 ... 750 ... 6000 1/min (% I
–6000 ... 1500 ... 6000 1/min (% I
–6000 ... 150 ... 6000 1/min (% I
–6000 ... 750 ... 6000 1/min (% I
–6000 ... 1500 ... 6000 1/min (% I
Technische handleiding – Applicatieregelaar MOVIDRIVE
Opmerking
)
N
)
N
)
N
)
N
)
N
)
N
®
MDX60B/61B