Nr.
FBG Index
dec.
2__
25_
250
8800
251
8801
252
8802
253
8465
254
8463
255
8812
3__
30_ / 31_
300 / 310
8515 /
8519
301 / 311
8516 /
8520
302 / 312
8517 /
8521
303 / 313
8518 /
8522
32_ / 33_
320 / 330
8523 /
8528
321 / 331
8524 /
8529
322 / 332
8525 /
8530
323 / 333
8526 /
8531
324 / 334
8527 /
8532
34_
345 / 346
9114 /
9115
Technische handleiding – MOVITRAC
Naam
Bereik / fabrieksinstelling
Display MOVITOOLS
Controller parameters
PI controller
PI controller
0
1
2
P gain
0 ... 1 ... 64
I-component
0 ... 1 ... 2000 [s]
PI actual
1
value mode
5
6
7
8
9
PI actual
0.1 ... 1.0 ... 10.0
value scaling
PI actual
0.0 ... 100.0 [%]
value offset
Motor parameters (op FBG alleen parameterset 1)
Limits 1 / 2
Start/stop
0 ... 150 [rpm]
speed 1 / 2
Minimum
0 ... 15 ... 5500 [rpm]
speed 1 / 2
Maximum
0 ... 1500 ... 5500 [rpm]
speed 1 / 2
Current limit 1 / 2
0 ... 150 [% I
Motor adjustment 1 / 2
Automatic
off
adjustment 1 / 2
on
Boost 1 / 2
0 ... 100 [%]
IxR
0 ... 100 [%]
compensation 1 / 2
Pre-magnetiza-
0 ... 2 [s]
tion time 1 / 2
Slip
0 ... 500 [rpm]
compensation 1 / 2
I
-UL monitoring
N
I
-U
0.1 ... 500 A
N
L
monitoring 1 / 2
®
B
Inbedrijfstelling
Parameterlijst
®
MotionStudio
Off
Normal
Inverted
10 V, reference maximum speed
0 - 20 mA, reference maximum speed
4 - 20 mA, reference maximum speed
0 - 10 V, n-reference
0 - 20 mA, n-reference
4 - 20 mA, n-reference
]
nom
Off
On
I
5
0 0
Waarde na
inbedrijf-
stelling
69