Nr.
FBG Index
dec.
1__
10_
100
8461
101
8462
102
8840
103
10247.15
104
10247.10
105
10416.1
106
10247.11
107
10247.12
108
10247.13
109
10247.14
11_
110
8463
112
8465
113
8466
116
10247.6
117
10247.7
118
10247.8
119
10247.9
Technische handleiding – MOVITRAC
Naam
Bereik / fabrieksinstelling
Display MOVITOOLS
Setpoints / ramp generators (on FBG only parameter set 1)
Setpoint selection / frequency input
Setpoint source
0
1
2
4
6
7
8
9
10
11
14
Control signal
0
source
1
3
4
Frequency scaling 0.1 ... 10 ... 120.00 [kHz]
FI1 reference
0
1
Setpoint reference
0 ... 3000 ... 6000 rpm
speed n
ref
Wire breakage
0
detection
2
4
7
FI1 char. curve x1
0 ... 100%
FI1 char. curve y1
–100% ... 0 ... +100%
FI1 char. curve x2
0 ... 100%
FI1 char. curve y2
–100% ... 0 ... +100%
Analog input 1 (0 ... 10 V)
AI1 scaling
0.1 ... 1 ... 10
AI1 operating
1
mode
5
6
7
8
9
AI1 voltage offset
–10 V ... 0 ... +10 V
AI1 char. curve x1
0 ... 100%
AI1 char. curve y1
–100% ... 0 ... +100%
AI1 char. curve x2
0 ... 100%
AI1 char. curve y2
–100% ... 0 ... +100%
®
B
Inbedrijfstelling
Parameterlijst
®
MotionStudio
Bipolar/fixed setpoint
Unipolar/fixed setpoint
RS-485/fixed setpoint
Motor potentiometer/fixed setpoint
Fixed setpoint + AI1
Fixed setpoint * AI1
MASTER SBus1
MASTER RS-485
SBus 1/fixed setpoint
Frequency setpoint input/fixed setpoint
Bipolar AI2/fixed setpoint
Terminals
RS -485
SBus 1
3-wire control
n
max
n
ref
No response
Immediate stop / fault
Rapid stop / fault
Rapid stop / warning
10 V, reference maximum speed
0 - 20 mA, reference maximum speed
4 - 20 mA, reference maximum speed
0 - 10 V, n-reference
0 - 20 mA, n-reference
4 - 20 mA, n-reference
I
5
0 0
Waarde na
inbedrijf-
stelling
67