Par. T2.3.4-B-1
Aansluiting van NA-5 (alle) op een DC-650
Geen compensator voor lijnspanning (verouderd)
AANSLUITSCHEMA DC-650 PRO/DC-750 NAAR NA-5 & NA-5R
AANSLUITEN MET AMPHENOL
STROOMBRON
14-PINS AMHENOL
VASTBOUTEN AAN KABELS VANAF NA-
5-DRAADCONTACTEENHEID
O.G.
O.A.
AANSLUITEN OP WERKSTUK
OPMERKING: BOVENSTAANDE SCHEMA'S GEVEN EEN POSITIEF GELADEN ELEKTRODE WEER. U WIJZIGT DE POLARITEIT DOOR DE STROOM UIT TE SCHAKELEN, DE ELEKTRODE EN DE
WERKSTUKKABELS ANDERS TE LADEN BIJ DE STROOMBRON EN DE STROOMBRONSCHAKELAAR OP DE JUISTE POLARITEIT TE ZETTEN. ZIE DE BEDIENINGSHANDLEIDING
VOOR NA-5 VOOR DE VEREISTE POLARITEITSAANSLUITINGEN VAN HET NA-5-BEDIENINGSKASTJE.
O.A. MAAT VAN LASKABELS MOET GESCHIKT ZIJN VOOR STROOMSTERKTE EN INSCHAKELDUUR VAN DE TOEPASSING.
O.B. VERLENG DRAAD #21A DOOR DRAAD #21A UIT DE CONTACTSTRIP TE VERWIJDEREN EN AAN TE SLUITEN OP EEN GEïSOLEERDE DRAAD #14 OF HOGER DIE FYSIEK GESCHIKT IS VOOR DE INSTALLATIE.
O.C. VERLENG DRAAD #21A MET EEN GEïSOLEERDE DRAAD #14 OF HOGER DIE FYSIEK GESCHIKT IS VOOR INSTALLATIE.
O.D. SLUIT DE VERLENGDE DRAAD RECHTSTREEKS AAN OP HET WERKSTUK WAARBIJ U DEZE APART HOUDT VAN DE LASWERKKABELAANSLUITING MET HET WERKSTUK.
LEID DEZE VERLENGDE DRAAD GEMAKSHALVE LANGS DE LASWERKKABEL.
O.E. TAPE DE AANSLUITING VAST.
O.F.
VOOR EEN JUISTE WERKING VAN NA-5 MOETEN DE ELEKTRODEKABELS GOED ONDER DE KLEMBALK LINKS VAN HET NA-5-BEDIENINGSKASTJE WORDEN WEGGEBORGEN.
O.G. SLUIT DE NEGATIEVE UITGANGSKABELS AAN OP AANSLUITINGEN VOLGENS DE DC650 PRO MODUSSCHAKELAARSINSTELLING.
O.H. DE JUMPERS OP DE NA-5 SPANNINGSKAART MOETEN ALS VOLGT WORDEN AANGESLOTEN: SLUIT RODE JUMPER AAN OP PIN "S".
O.J.
ALS U EEN OUDERE K-215-STUURSTROOMKABEL GEBRUIKT: SLUIT DRAAD #75 AAN OP #75 OP CONTACTSTRIP, SLUIT DRAAD #76 AAN OP #76 OP DE CONTACTSTRIP, SLUIT DRAAD #77 AAN OP #77 OP DE CONTACTSTRIP.
O.K. SLUIT DE AARDINGSDRAAD VAN DE NA-5-STUURSTROOMKABEL AAN OP DE GEMARKEERDE FRAME-AANSLUITING
STUURSTROOMKABEL
STROOMBRON
O.H.
NAAR NA-5-
INGANGSKABELSTEKKER
O.B., O.D., O.E.
O.E., O.F.
O.G.
SLUIT WITTE JUMPER AAN OP PIN "B".
AANSLUITEN MET CONTACTSTRIP
STUURSTROOMKABEL
O.K.
O.C., O.D.,O.E.
VASTBOUTEN AAN KABELS
VANAF NA-5-
DRAADCONTACTEENHEID
O.A.
AANSLUITEN OP WERKSTUK
DICHT BIJ DE CONTACTSTRIP VAN DE STROOMBRON.
DC650 PRO
STROOMBRONINSTELLINGEN
O.H.
1. SCHAKEL HET INGANGSVERMOGEN UIT.
NAAR NA-5-
INGANGS-
2. SLUIT ELEKTRODEKABELS AAN OP
KABEL-
AANSLUITINGEN MET DE GEWENSTE POLARITEIT.
STEKKER
3. STEL TUIMELSCHAKELAAR IN OP DEZELFDE
POLARITEIT ALS DE
O.J.
ELEKTRODEKABELAANSLUITING.
4. STEL DE TUIMELSCHAKELAAR IN OP EXTERN.
5. STEL MODUSSCHAKELAAR IN OP DE GEWENSTE
POSITIE VOOR HET TE GEBRUIKEN PROCES.
6. SLUIT NEGATIEVE UITGANGSKABELS AAN
VOLGENS INSTELLING MODUSSCHAKELAAR.
O.E., O.F.