2 - INSTALLATION
2.1 - UNIT POSITIONING
Avoid installing the unit:
-
in positions subject to direct exposition to sun rays;
-
next to sources of heat;
-
in humid environments and zones with probable contact with water;
-
in environments with oil vapours
WARNING
A failure to apply the indicated standards, which may cause malfunctioning
of the equipment, relieves the company OLIMPIA SPLENDID from any form of
warranty and from possible damages caused to people, animals or property.
Make sure that:
a. The wall on which it is desired to install the unit has a suitable structure and capacity;
b. The involved zone of the wall is not travelled by pipelines or power lines;
c. The involved wall is perfectly flat;
d. There is an area free from obstacles which may hinder inlet and outlet air circulation;
e. The wall for installation is, possibly, an external perimeter wall in order to allow for drainage of
condensation to the exterior.
If it is not possible, please envisage a suitable drainage line for condensation.
f. In case of high installation, the air flow is not targeted directly against people.
g. The appliance must be installed in such a position as to allow for easy ordinary and extraordinary
maintenance, as well as for easy access to the air breather valves which can be reached from
the upper grille of the connections side.
2.2 - MODE OF INSTALLATION
The following descriptions on the various phases of assembly and the corresponding drawings refer to a
version of the machine with connections to the left.
The descriptions for the assembly operations of the machines with connections to the right are the same.
Only the figures must be considered as shown specularly.
2.3 - OPENING THE UNIT
2.3.a - Models with flap (Fig.3)
a. Delicately rotate the air outlet flaps 90°.
b. Undo the 4 fixing screws highlighted in the figure.
c. Make the front part tilt slightly, then raise it.
d. Disconnect the command display-board connector.
2.4 - WALL OR VERTICAL FLOOR INSTALLATION
In case of floor installation with the supports, refer to the instructions supplied with the specific kit for their
assembly.
a. Use the template in the packaging (to be cut along the indicated lines) and mark on the wall the position
of the two fixing brackets (fig. 4).
b. Drill using an appropriate bit and insert the dowels (T), 2 for each bracket (fig. 4).
c. Secure the two brackets (S) (fig. 5). Do not tighten the screws excessively, so as to be able to adjust the
brackets using a bubble level (fig. 6).
EN - 9