11. Checking the power supply
Warning
Before starting any work on the pump/
motor, make sure that the power supply
has been switched off and that it cannot be
accidentally switched on.
1. Supply voltage
L
N
PE
2. Current consumption
12. Environment
During handling, operation, storage and transport,
all environment regulations dealing with the handling
of hazardous materials must be observed.
Warning
When the pump is taken out of operation, it
must be ensured that no hazardous
material is left in the pump/motor and the
riser pipe, which can be injurious to
persons and the environment.
In case of doubt, please contact Grundfos or the
local authorities.
13. Disposal
This product or parts of it must be disposed of in an
environmentally sound way:
1. Use the public or private waste collection service.
2. If this is not possible, contact the nearest
Grundfos company or service workshop.
Measure the voltage (RMS)
between phase and neutral.
Connect the voltmeter to the
terminals at the connection.
Measure the current (RMS)
while the pump is operating
at a constant discharge head
(if possible, at the capacity
where the motor is most
heavily loaded).
For maximum current, see
nameplate.
Subject to alterations.
The voltage should, when the motor is
loaded, be within the range specified in
section
5. Electrical
connection.
Large variations in supply voltage indicate
poor power supply, and the pump should be
stopped until the defect has been remedied.
If the current exceeds the full load current,
there are the following possible faults:
• Poor connection in leads, possibly in the
cable joint.
• Too low supply voltage, see item 1.
19