3.3.1. Data plate
1Ph
3Ph
No.
1 Ph
1
Typ description
2
Serial number
3
Impeller diameter
Temperature of medium
4
5
Immersion depth
6
Weight
7
Hmax (delivery head max)
8
Hmin (delivery head min)
9
Qmax (delivery volume max) Qmax (delivery volume max)
10
Standard
11
Construction product test lab
12a
Year type test
12b
Declaration of performance
13
Build year
14
Motor type
15
IE Marking
16
Frequency
17
Voltage
18
Nominal current
19
Motor RPM
20
Power P1
21
Cos phi
22
Insulation class
23
Power P2
24
Start condenser
25
Operating condenser
26
Protection class
27
Operating class
Text field sales
28
24 | ENGLISH
3 Ph
Typ description
Serial number
Impeller diameter
Temperature of medium
Immersion depth
Weight
Hmax (delivery head max)
Hmin (delivery head min)
Standard
Construction product test lab
Year type test
Declaration of performance
Build year
Motor type
IE Marking
Frequency
Voltage - 3Phase
Nominal current - 3Phase
Motor RPM
Voltage - Star Connection
Nominal current Star connection
Insulation class
Power P1
Cos phi
Protection class
Power P2
Operating class
Text field sales
3.3.2. Motor
The motor consists of a stator and the motor shaft with
the rotor set. The lead for supplying power is designed
for the maximum mechanical power in accordance with
the characteristic curve or data plate of the pump. The ca-
ble entries and the lead are sealed watertight against the
conveyed medium. The shaft bearings are robust, mainte-
nance-free and permanently greased roller bearings.
General motor data
Mode of operation
Permissible medium temperature
Insulation class
IP Code
Cable length
Voltage version W
Voltage version D

3.3.3. Monitoring systems

Direction of rotation control
No check is necessary for 1ph motors , since these al-
ways run in the correct direction of rotation.
3ph motors run in the correct direction of rotation when
connected to a anticlockwise rotating field (U, V, W -> L1,
L2, L3). HOMA switchgear checks the grid for a clockwise
rotating field. With smaller pumps, the check can be made
by observing the starting jerk. For this purpose, place the
pump perpendicular to the floor, slightly on edge, and
switch on briefly. Seen from above, the pump jerks slightly
clockwise if the direction of rotation is correct.
The direction of rotation of the pump is correct if the pump
moves clockwise because, seen from above, the motor
starts in the anticlockwise direction.
Warning of rotating blade wheel.
Do not touch the rotating blade wheel or reach
through the discharge outlet into the pump chamber!
During operation, never reach into the pump cham-
ber or touch rotating parts. Before maintenance or
repair work, shut the machine off and let the rotating
parts come to a standstill.
It is also possible to check the direction of rotation with
a "motor and phase rotation indicator" . This measuring in-
strument is held externally against the motor housing of
the running pump: it shows the direction of rotation with
an LED.
S1 at 20 starts per
hour
30°C
B (130°C)
IP68
1 m
230V / 50Hz / 1Ph
400V / 400V / 3Ph