n
kVA
Inbedrijfstelling
5
f
Parameterlijst
i
P
Hz
Nr.
FBG Index
43.
430
431
432
433
44.
440
441
442
45.
450
451
5..
50.
500 / 502
501 / 503
54.
540
541
542
543
544
545
549
56.
560
561
562
563
564
565
566
66
Naam
dec.
Current reference signal
8550
Current reference
value
8551
Hysteresis
8552
Delay time
8553
Signal = "1" when
Imax signal
8554
Hysteresis
8555
Delay time
8556
Signal = "1" when
PI controller reference signal
8813
PI actual value
reference
8796
Signal = "1" when
Control parameters (op FBG alleen parameterset 1)
Speed monitoring 1 / 2
8557 /
Speed monitoring
8559
1 / 2
8558 /
Delay time 1 / 2
8560
Gear unit / motor monitoring
9284
Response to drive
vibration / warning
9285
Response to drive
vibration / fault
9286
Response to oil
aging / fault
9287
Response to oil
aging / warning
9288
Oil aging / over-
temperature
9289
Oil aging / ready
signal
9290
Response to
brake wear
Current limit Ex-e motor
9293
Current limit Ex-e
motor
9294
Frequency A
9295
Current limit A
9296
Frequency B
9297
Current limit B
9298
Frequency C
9299
Current limit C
Bereik/fabrieksinstelling
®
Display MOVITOOLS
MotionStudio
0 – 100 – 150% I
N
0 – 5 – 30% I
N
0 – 1 – 9 s
0
I < I
ref
1
I > I
ref
0 – 5 – 50% I
N
0 – 1 – 9 s
0
I < I
max
1
I > I
max
0.0 – 100.0 %
0
Actuele waarde PI < PI ref
1
Actuele waarde PI > PI ref
0
Uit
3
Motorisch/generatorisch
0 – 1 – 10 [s]
Fabrieksinstelling: Display error
Fabrieksinstelling: Rapid stop/warning
Fabrieksinstelling: Display error
Fabrieksinstelling: Display error
Fabrieksinstelling: Display error
Fabrieksinstelling: Display error
Fabrieksinstelling: Display error
ON / OFF
0 – 5 – 60 Hz
0 – 50 – 150%
0 – 10 – 104 Hz
0 – 80 – 200%
0 – 25 – 104 Hz
0 – 100 – 200%
Technische handleiding V3 – MOVITRAC
Waarde
na inbe-
drijfstel-
ling
®
B