DISPLAY / FAILURES

Below on the display you can read the actual working hours of the machine
and you can check if the antifreeze filling function is active. Centrally you can
read the working pressure and the output temperature. Left on top the engine
speed setting will be displayed (100% is similar to the max. adjusted pressure,
in example below: 250 Bar. When the engine speed setting is 50%, the working
pressure will visualize 125 bar).
Remark: the machine will go automatically to the 'high
temperature funcion' if the function valve is activated.
Right on top the setting temperature will be displayed. Setting: 0°C= burner off &
1°C or more= stand- by temperature.
It can be that the actual temperature has a higher value than
the setting temperature, the burner will not work until the
actual temperature is lower than the setting temperature.
Temperature settings
Determine experimentally which engine speed (spray pressure) and at which
temperature the object best can be cleaned without damaging it. Protein-
containing material, rubber or synthetic material: knob not higher than 50°C.
For the other settings the most diverge materials and/or machines will be
cleaned. Therefore, there are no fixed settings to be displayed.
High cleaning temperatures
A cleaning temperature of more than 95°C can only be obtained by reducing
the number l/min produced by the high pressure pump. By ( min. pressure, min
flow) reducing the engine speed setting on the display one reduces the number
of l/min. The temperature shall increase maximum until the set value is reached.
If the flow is low, the flow switch shall put the burner out of use, to prevent that
the temperature will increase.
Right below there's an indication if the burner is active or not (through
indication of flame/ strikethrough flame).If you move the control stick 1x up & 1x
down, the burner will turn off. Temperature indication then becomes 0° C. The
burner hours are visible on the home screen if pushed on the clock key (see
photo at the bottom right). These burner hours will only be visible at the time of
pushing the (clock) key.
1

Settings with control stick

The screen includes a number of possible operating pages as shown on this
page (depending the selected options) when the control stick is operated.
General: when not operating the control stick, the control unit will automatically
return for 20 seconds to the main screen.
1 C O N T R O L S C R E E N 1 ( O P E R AT I N G I N S T R U C T I O N S )
In this screen you can choose to check the various operating instructions.
Move the control stick to the left (no) or right (yes) to select.