    C O M P O N E N T S
9 F U E L P U M P
The fuel pump is driven by the burner motor. On the fuel pump is an magnetic
valve assembled which ensures that the fuel either gets to the burner (pumped)
or gets back to the fuel tank.
10 F R A M E
The frame is made of a powder coated steel construction. The frame has cut-
outs below the machine to transport easily (by forklift). Below the frame, a plate
is mounted at the frame (side in front) to service easliy (electric box).
11 A LT E R N ATO R
The alternator serves to generate a tension (12 V) for power supply of the
electric parts.
12 S A F E T Y VA LV E
When the water pressure increases above the preset safety pressure, the safety
valve opens and the water flows pressureless below the cleaner.
13 F LOW S W I TC H ( E S )
As soon as there is sprayed, water flows through the flow switch. The switch
controls if there is a flow of water. At sufficient flow the burner can function.
14 B U R N E R
The type of burner depends on the type of cleaner. The 'green burner' is a
burner that makes a higher efficiency. The burner provides hot water. The
temperature of the water is adjustable. The burner is double- walled. The
outside wall is air cooled by the ventilator lateral on the burner chamber. On top
of the burner one can find the burner mouth. The water supply and outlet are
both situated at the bottom of the burner.
Lime scale deposits while working at higher temperatures
The hardness of the water is possible expressed in French degrees (°F) or
German degrees (°D). The difference is noticeable in the following equation:
1 ° F = 0.56 ° D. For example, water having a hardness of 40 ° F has a German
hardness of 40 x 0.56 = 22.4 ° D. See the in your area prescribed hardness of
drinking water. Hard water can cause problems by means of lime scale from
30°F or 17°D.
When hardened water is now warmed / heated / or being pumped (or when
hard water comes in contact with air), this can cause calcification. Hard water is
caused mainly by the presence of two components: calcium and magnesium.
So the harder the water, the more chances on lime scale! When cleaning with
high temperatures (or at using heated water) , you obtain thus faster calcification
in case of a low hardness! This can therefore result in loss of energy efficiency,
higher energy consumption and reduced capacity of water supply (including
calcium deposits on the burner coil and other water connection parts).
We, DIBO NV, therefore recommend to decalcify the machines with a burner
preventive additionally and after use of hot water rinse adequate with cold
water (if possible) to ensure optimum performance of the machine!
15 A DJ U S T M E N T VA LV E BY PA S S
Through the adjustment valve one can regulate the bypass pressure so that the
pressure control valve is functioning properly (eg when working at high altitude).
This valve is factory set.
16 S A F E T Y T H E R M O S TAT C H I M N E Y
If the temperature on the temperature probe exceeds the setpoint value. The
chimney thermostat will now arrange that the fuel valve and the burner motor
will be interrupted directly. The chimney thermostat can only be reset by means
of pushing the green reset button on the thermostat (first unscrew the black
protection) in the burner electric box.