Note: If the filter is clogged or the grille is unintentionally
covered, a special sensor will stop the blower heating.
Normal operation of the unit will resume the next time it
is switched on if the filter or grille is not blocked and only
after the blower has cooled down.
- If the room temperature reaches the maximum
Boost temperature during the countdown:
The blower stops
but the Boost mode
mode is still active:
the countdown is still
is still displayed, the
symbol and the heating lamp are flashing. When the
temperature drops below the maximum temperature
allowed, the blower will be reactivated until the end of the
countdown.
Second press = cancel boost.
-
The mode indicator returns to the previously active mode
and the
and the set temperature is displayed.

POST-VENTILATION

When the blower is switched off, the ventilation continues
for a few seconds after the heater has been switched off
in order to preserve and optimise
the life of the product.
A countdown appears on the
display and the keys keys
remain inactive during this period

SUPER COMFORT

The blower can be used as an additional instantaneous
heater if there is a significant difference between the room
temperature and the desired setpoint temperature. The
Super Comfort is activated if the difference between the
room temperature and the target temperature is greater
than 2°C. The Super Comfort is activated by default (see
chapter User settings page 14 and subchapter Super
Comfort page 14).
Example: The appliance is in Eco setpoint 17.5°C, you
decide to switch to Comfort mode: the difference between
21°C and 17.5°C is 3.5°C, therefore greater than 2°C.
The blower will automatically
start to help the temperature rise
and reach the required 21°C.
The heating and Boost
indicators appear on the display
and the mode indicator below the selected mode flashes.
ScF et la température de consigne Super confort appa-
raissent sur l'afficheur alternativement.
The super comfort stops if:
- The difference is less than 0.5°C.
- The difference is always greater than 2°C after 1 hour of Super
Comfort.
Note: Super Comfort is only valid in Comfort and
Auto-Comfort mode.

CONSUMPTION GAUGE, ENERGY SAVING

In the display, a selector indicates the level of energy
consumption by automatically positioning itself in front of
a colour: red, orange or green.
Thus, depending on the set temperature, you can now
determine your energy consumption level
The higher the temperature setting, the higher the con-
sumption.
The gauge appears in Auto, Comfort, Eco and Frost
Protection modes, regardless of the temperature level.
C - Red colour
Setpoint > 22°C
Temperature level high:
When the temperature
it is recommended to
setpoint is
reduce temperature
higher than 22°C
significantly.
B - Orange colour
19°C < Set point ≤
Temperature level
22°C
medium :
When the temperature
it is advisable to slightly
setpoint is
reduce the temperature
higher than 19°C and
less than or equal to
22°C
A - Green colour
Setpoint ≤ 19°C
Temperature level
When the temperature
ideal.
temperature is
less than or equal to
19°C

COMFORT TEMPERATURE SETTING

The Comfort temperature setting is only accessible from
the Auto and Comfort modes. It is preset to 19°C.
Using
and
you can adjust the temperature from
7°C to 30°C in 0.5°C steps.
Note: This temperature setting range can be limited, see
page 15, subchapter Comfort temperature limitation.
INDICATION OF CUMULATIVE
CONSUMPTION IN kWh, ENERGY SAVING
You can see the estimated energy in kWh consumed by
the appliance since the energy meter was last reset.
Visualisation of estimated energy consumption
To view this estimate, from the Auto,
Comfort, Eco or Frost protection
mode, press
.
To exit the consumption display mode
mode: press
or
appliance automatically returns to the previously active
mode.
Resetting the energy meter
To reset the counter from Auto,
Comfort, Eco or Frost protection mode, proceed as
follows.