EXPERT SETTINGS
ACCESS
- After installation of the towel dryer components, it is necessary to initialise the various components via the "expert
settings" menu of the fan module. The expert settings are accessed in 5 steps; from the Auto, Comfort, Eco or Frost
protection mode.
information
1
display
1 long press
5 seconds
information
display
Expert Settings flowchart:
Calibration of the room temperature sensor
Limit of the internal heating temperature
CALIBRATION OF THE ROOM TEMPERATURE SENSOR
Important: This operation is reserved for professional installers only, any incorrect modification will result in
control anomalies.
In which case? If the temperature obtained in the room (by a reliable thermometer) is different by at least 1 or 2
degrees from the set temperature you request on the device. Calibration allows you to act only on the temperature
measurement by the device's probe in order to compensate for a possible difference, from +5°C to -5°C by steps of
0.1°C.
Calibration of the sensor
1- If the temperature difference is negative, for example: Set temperature
(what you want) = 20°C. Room temperature (what you read on a reliable
thermometer) = 18°C.Measured difference = - 2°C.
Important: Before proceeding with the calibration, it is advisable to
wait 4 hours after a change in the setpoint temperature to ensure that
the room temperature has stabilised.
To correct the deviation, proceed as follows:
Sensor temperature reading = 24°C.
(The measured temperature is often different and higher than the set
temperature).
Decrease the temperature measured by the sensor by 2°C using the
key.
In our example the temperature measured by the sensor drops from 24°C
to 22°C.
2
2 short
presses
4
1 long press and
10 seconds simultaneously
Return to factory settings
PRO = expert
settings
Choice of the type of energy
information
displays
5
1 short press
Choice of power
3
1 long press
10 seconds
6