DANGER: Do not handle pressurized hoses. Escaping
oil under pressure can penetrate the skin, causing
serious injury. If oil is injected under the skin, see a
doctor immediately.
WARNING: Only use hydraulic cylinders in a coupled system.
Never use a cylinder with unconnected couplers. If the
cylinder becomes extremely overloaded, components can
fail catastrophically causing severe personal injury.
WARNING: BE SURE SETUP IS STABLE BEFORE
LIFTING LOAD. Cylinders should be placed on a flat
surface that can support the load. Where applicable, use
a cylinder base for added stability. Do not weld or otherwise
modify the cylinder to attach a base or other support.
Avoid situations where loads are not directly centered on
the
cylinder
plunger.
considerable strain on cylinders and plungers. In addition,
the load may slip or fall, causing potentially dangerous results.
Distribute the load evenly across the entire saddle surface.
Always use a saddle to protect the plunger.
IMPORTANT: Hydraulic equipment must only be serviced
by a qualified hydraulic technician. For repair service,
contact the Authorized ENERPAC Service Center in your
area. To protect your warranty, use only ENERPAC oil.
WARNING: Immediately replace worn or damaged parts
with genuine ENERPAC parts. Standard grade parts will
break causing personal injury and property damage.
ENERPAC parts are designed to fit properly and withstand high
loads.
3.0 DESCRIPTION
The 10,000 psi TURBO II Air Pumps have an operating pressure
of 10,000 psi at 85 psi inlet pressure. They are suited for plant
maintenance, fabrication, production, bolting, vehicle repair, and
any task that requires hydraulic pressure from air input.
4.0 SPECIFICATIONS
See the table below .
SPECIFICATION TABLES
Model
Weight-add 1 lb.
No.
[.5 kg] for bracket
PATG1102N
18 lbs. [8,2 Kg]
PATG1105N
22 lbs. [10,0 Kg]
PAMG1402N
24 lbs. [10,9 Kg]
PAMG1405N
26 lbs. [11,8 Kg]
PARG1102N
22 lbs. [10,0 Kg]
PARG1105N
26 lbs. [11,8 Kg]
Model
Hydraulic
Type
Air Ratio
PATG,
100:1
PAMG
PARG
100:1
Off-center
loads
Reservoir
Series
2
5
Hydraulic
Oil Flow
Output Ports
@ 100 psi
[6.9 bar]
.375-18 NPTF
60 cu.in/min.
[1.0 liters/min.]
.375-18 NPTF
45 cu.in/min.
[0.74 liters/min.]
5.0 INSTALLATION
5.1 Air Supply
Pump operates with 25-125 psi [2,76 - 8,27 bar] air pressure. An
Enerpac RFL-102 (regulator/filter/lubricator) should be installed
upstream from pump to provide clean, lubricated air and allow for
air pressure adjustment.
5.2 Air Connections
See Illustration 1. Attach air supply to the
connection on the end of the pump. Use Teflon tape or similar
thread sealant. Torque to 20-25 ft. lbs [27-34 Nm].
PARG Models: See Illustrations 2 and 3. Attach air supply to
either 1/4 NPT connections on top rear to handle or 1/4 NPT
connection on bottom of air pendant. Make sure the unused port
produce
is plugged.
5.3 Hydraulic Connections
Model Numbers
Ending In
N or NB
P or PB
1
/
NOTE: Use 1
leaving the first complete thread free of tape to ensure that pieces
of tape do not break off and enter the system. Do not use tape
sealant on BSPP fittings.
PAMG, PARG and PATG Models: See illustration 4. Thread
hose(s) into outlet port(s) of pump (A). Hose fittings must be
torqued. See Torque Specifications Table. Pumps with treadles
(PATG) have one outlet port, and pumps with 4-way valves
(PAMG) have 2 outlet ports. Outlet port(s) are located on the
opposite end of pump from the air inlet connection.
NOTE: Valve block or treadle should be restrained when torquing
fittings. The reservoir base should not be bolted down or
restrained to compensate for the fitting installation torque.
Reservoir
Capacity
137 cu.in
[2.2 liters]
265 cu.in
[4.3 liters]
Oil Flow
Air Pressure
@ 10,000 psi
Range
[700 bar]
10 cu.in/min.
25-125 psi
[0.16 liters/min.]
[ 1,7-8,6 bar]
5 cu.in/min
25-125 psi
[0.08 liters/min.]
[ 1,7-8,6 bar]
2
TORQUE SPECIFICATIONS
Hydraulic Ports
3
/
NPTF
8
1
/
BSPP
4
wraps of Teflon tape the NPTF hose fittings only,
2
Usable Oil Capacity
(horizontal mounting)
127 cu.in
[2.1 liters]
230 cu.in
[3.8 liters]
Air
Consumption @
100 psi [6.9 bar]
12 SCFM
[0.34 cu.m/min]
12 SCFM
[0.34 cu.m/min]
1
/
NPT swivel
4
Torque Fittings To
65 – 75 ft-lbs.
[88–102 Nm]
14 – 18 ft-lbs.
[19 – 24 Nm]
Operating
Noise
Level (dBA)
76
76