Download Inhoudsopgave Inhoud Print deze pagina

ims PRO PULSEMIG 220 C Gebruikershandleiding pagina 32

Mig/mag - tig - mma lasapparaat
Inhoudsopgave

Advertenties

Operating manual
Standard (constant current)
2 mm
D
CHOOSING THE ELECTRODE'S DIAMETER
Electrode Ø (mm)
1
1.6
2
2.5
3.2
4
USING THE TRIGGER
• 2T
t
Bouton principal
T1
t
t
Bouton principal
T1
• 4T
Bouton principal
T1
Bouton principal
T1
T2
Bouton principal
T1
T2
Bouton principal
T1
T2
• 4T LOG
Bouton principal
T1
T2
Bouton principal
T1
T2
Bouton principal
T1
T2
32
Translation of the original
instructions
10 mm
5 mm
D
D
Pure tungsten
t
t
t
T2
T2
T2
t
t
t
t
t
t
T3
T3
<0.5s
<0.5s
>0.5s
T3
<0.5s
<0.5s
>0.5s
<0.5s
<0.5s
>0.5s
t
t
t
t
t
t
T4
T3
T4
T3
T4
T3
5 mm
D
10 > 75
60 > 150
75 > 180
130 > 230
160 > 310
275 > 450
Approx. = 80 A per mm Ø
T1 - The main button is pressed, the welding cycle starts (Pre-Gas,
I_Start, upslope and welding).
T2 - The main button is released, the welding cycle is stopped
(downslope, I_Stop, Post-Gas).
For two-button torches in T2 only, the secondary button is treated as
the main button.
T1 - The main button is pressed, the cycle starts from Pre-Gas and
stops at the I_Start phase.
T2 - The main button is released, the cycle continues to upslope
and welding.
T3 - The main button is pressed, the cycle goes to downslope and
stops in the I_Stop phase.
T4 - The main button is released, the cycle ends with the Post-Gas.
NB: for torches, double buttons and double button + potentiometer
T4
=> «up/weld current» button turns on the potentiometer, the «down»
button turns it off.
T4
T4
T1 - The main button is pressed, the cycle starts from Pre-Gas and
stops at the I_Start phase.
T2 - The main button is released, the cycle continues to upslope
and welding.
LOG: this operating mode is used during the welding phase:
- a quick press of the main button (<0.5 s) switches the current from
I_welding to I_cold and vice versa.
- if the secondary button is pressed, the current switches from
I_welding to I_cold.
- if the secondary button is left unpressed, the current switches from
I_cold to I_welding.
T3 - After holding down the main button (>0.5 s), the cycle goes into
downslope and stops at the I_Stop phase.
T4 - The main button is released and the cycle ends with Post-Gas.
PULSEMIG 220 C / 220 C XL
E-TIG (constant power)
2 mm
D
D
TIG DC
Tungsten with oxides
10 > 75
60 > 150
100 > 200
170 > 250
225 > 330
350 > 480
10 mm

Advertenties

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

Pulsemig 220 c xl

Inhoudsopgave