POWER SWITCH
• The material is supplied with a 16A plug type CEE7/7 and must only be used on a single-phase electrical installation 230V (50-60 Hz) with 3 wires
including one connected to earth. The absorbed effective current (I1eff) is indicated on the machine, for optimal use. Check that the power supply and
its protections (fuse and/or circuit breaker) are compatible with the current needed by the machine. In some countries, it may be necessary to change
the plug to allow the use at maximum settings. The user must ensure that the plug remain accessible.
• The machine is designed to work on a 230V -20% +15% power supply. It switches to protection mode if the power supply voltage is below 185V RMS or over
265V RMS. (a default code will appear on the screen display).
• To switch the machine on, turn the on/off switch (I-3) to position I, whereas switching it off is done by turning the switch to position 0. Caution! Never
disconnect the machine from the power supply while the machine is charging.
CONNECTING TO A POWER SOURCE
This equipment can be operated with electric generators provided that the auxiliary power supply meets the following requirements:
- The voltage must be alternating, its RMS value must be 230 V -20% +15%, and the peak voltage must be less than 400 V.
- The frequency must be between 50 and 60 Hz.
It is vital to check these conditions as many generators produce high voltage peaks that can damage equipment.
USING EXTENSION LEADS
All extension leads must be of a suitable length and width that is appropriate to the equipment's voltage. Use an extension lead that complies with
national safety regulations.
Input voltage
230 V
SETTING UP THE REEL
a
b
b
a
LOADING THE FILLER WIRE
a
b
- Check the inscription on the roller to ensure that the rollers are suitable for the wire diameter and
the wire material (for a Ø 1.2 wire, use the Ø 1.2 groove).
- Use V-grooved rollers for steel and other hard wires.
- Use U-grooved rollers for aluminium and other soft, alloyed wires.
: visible inscription on the roller (example: 1.2 VT)
: groove to use
Translation of the original
instructions
Length - Size of the extension cord (Length < 45m)
2.5 mm²
- Remove the nozzle (a) and contact tube (b) from your MIG/MAG torch.
Open the power source's hatch.
- Position the reel on its holder.
- Take into consideration the reel stands's drive lug (c). To fit a 200 mm reel, tighten the
plastic reel holder (a) to the maximum. To fit a
c
advise using the attachment (chock) that comes supplied with the product.
- Adjust the brake wheel (b) to prevent the non-moving spool from tangling the wire when
the welding stops. In general, do not overtighten, as this will cause the motor to overheat.
To change the rollers, do the following:
- Unscrew the knob (a) as far as possible and lower it.
- Unscrew the rollers' retaining screws (b).
- Insert the appropriate motor rollers for your current welding application and retighten the
retaining screws.
The rollers supplied are double groove steel rollers (0.8 and 1.0).
PULSEMIG 220 C / 220 C XL
200 mm reel on the 220 C XL model, we
25