Translation of the original instructions
MADE IN FRANCE
The machine has been designed to minimise the risks due to electromagnetic fields. Some residual risks
persist and it is recommended to observe a security distance between the inductor and the operator's
head/torso.
Heat on standby
For security reasons, the product deactivates the heat authorisation after 5 minutes of inactivity. The heat authorisation
button indicator and the lance support LED both switch off.
To reactivate the machine, press the heat authorisation button (2) or press and hold the lance button (11) for 1 second.
This feature is disabled after 20 minutes of inactivity.
It allows the user to stay in a working position without the need to reach for the machine.
INDUCTOR PRESERVATION
The heated metal radiates heat on to the inductor at the square of the temperature to which it is heated. The inductor
is therefore highly exposed. When the metal is dark red, the temperature is below 850°C. If it turns bright red/or-
ange, the temperature exceeds 1000°C. If it turns white, the temperature exceeds 1200°C
(the chart below is available in colour on the website manual).
600 °C
To preserve the inductor and extend its life, it is necessary to keep the temperature around 850°C as much as possi-
ble and avoid prolonged use.
The ferrite included in the inductor has a higher coefficient of expansion than its mechanical support. Excessive heat-
ing of the inductor causes distortion to the ferrite. It is up to the user to avoid this excessive heating.
Therefore, the inductor, or ferrite when they are removable, are consumables to which the warranty does
not apply.

WARNING LIGHTS

- The indicator 6 signals a machine/inductor fault.
- The indicator 7 signals a cooling circuit liquid flow fault.
- The indicator 8 signals a thermal protection of the power block or the excessive temperature of the cooling liquid
which is 60°C/140°F.
Wait for the indicator to switch off and the machine is ready to operate.
The display 5 displays the fault code :
Fault code
E - 1
Heat authorisation button (2) is stuck.
E - 2
Lance button (11) is stuck.
E - 3
Keypad buttons are stuck (9) and (11).
E - 4*
Inductor intensity is too high or not compatible.
E - 5*
Inductor intensity is too low.
E - 6
Flow is too high >6 l/min.
E - 7
Flow too low <4 l/min.
E - 8*
Internal fault.
E - 9
Voltage network fault.
E - 10
Power-up fault
E - 11
Regulation temperature measurement fault
E - 12
The temperature does not change during heating
E - 13
Power relay fault.
E - 14
Power-up fault
- - -
Overvoltage fault.
No phase
+
*In the case of faults E-4, E-5 and E-8, restart the product after correcting the fault.
Fault code E5
Inductor screwing problem :
(check screwing, be careful not to overtighten!)
POWERDUCTION 110LG / 160LG / 220LG
Fault code E6
Flow rate fault refer to pages 6, 7 & 13
900 °C
In short-circuit or mechanically blocked.
In short-circuit or mechanically blocked.
In short-circuit or mechanically blocked.
Faulty lance or inductor in short circuit.
Inductor is not screwed properly or faulty lance.
Pierced hose or missing inductor.
Hose is pinched or obstructed, the pump does not operate.
Disconnected flat command cable.
The network voltage is too low.
Pneumatic pedal active when powered up.
The temperature sensor is off or short-circuit.
Incorrectly positioned temperature sensor.
Connection cable unplugged.
The pneumatic foot pedal is active at power-up when the
Powerduction Heat Controler is connected to the product.
Voltage above 460 V sector.
Disconnected phase in socket / product or fuse / switch
off
Fault code E7
Flow rate fault refer to pages 6, 7 & 13