Parameterlijsten
5.1.3 1-** Belasting & motor
Par.
Parameterbeschrijving
nr.
1-0* Alg. instellingen
1-00
Configuratiemodus
1-03
Koppelkarakteristiek
1-06
Clockwise Direction
1-2* Motordata
1-20
Motorverm. [kW]
1-21
Motorverm. [PK]
1-22
Motorspanning
1-23
Motorfrequentie
1-24
Motorstroom
1-25
Nom. motorsnelheid
1-28
Controle draair. motor
1-29
Autom. aanpassing motorgeg. (AMA)
1-3* Geav. Motordata
1-30
Statorweerstand (Rs)
1-31
Rotorweerstand (Rr)
1-35
Hoofdreactantie (Xh)
1-36
Ijzerverliesweerstand (Rfe)
1-39
Motorpolen
1-5* Bel. onafh. inst.
1-50
Motormagnetisering bij nulsnelheid
1-51
Min. snelh. norm. magnetisering [TPM]
1-52
Min. snelh. norm. magnetisering [Hz]
1-58
Flystart Test Pulses Current
1-59
Flystart Test Pulses Frequency
1-6* Bel. afhank. inst.
1-60
Belast. comp. bij lage snelheid
1-61
Belastingcomp. bij hoge snelheid
1-62
Slipcompensatie
1-63
Slipcompensatie tijdconstante
1-64
Resonantiedemping
1-65
Resonantiedemping tijdconstante
1-7* Startaanpassingen
1-71
Startvertraging
1-73
Vlieg. start
1-77
Compressor Start Max Speed [RPM]
1-78
Compressor Start Max Speed [Hz]
1-79
Compressor Start Max Time to Trip
1-8* Stopaanpassingen
1-80
Functie bij stop
1-81
Min. snelh. functie bij stop [RPM]
1-82
Min. snelh. voor functie bij stop [Hz]
1-86
Uitsch lg snelh [tpm]
1-87
Uitsch lg snelh [Hz]
1-9* Motortemperatuur
1-90
Therm. motorbeveiliging
1-91
Ext. motor-ventilator
1-93
Thermistorbron
®
VLT
HVAC Drive Programmeerhandleiding
Standaardwaarde
(SR = afhankelijk van grootte)
ExpressionLimit
[3] Auto Energie Optim. VT
[0] Normal
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
[0] Uit
[0] Uit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
100 %
ExpressionLimit
ExpressionLimit
30 %
200 %
100 %
100 %
0 %
ExpressionLimit
100 %
5 ms
0.0 s
[0] Uitgesch.
ExpressionLimit
ExpressionLimit
5.0 s
[0] Vrijloop
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
[4] ETR-uitsch. 1
[0] Nee
[0] Geen
®
MG.11.CA.10 – VLT
is gedeponeerd handelsmerk van Danfoss
4-set-up
Wijzigen
Conversie-
tijdens
index
bedrijf
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
Type
-
Uint8
-
Uint8
-
Uint8
1
Uint32
5
5
-2
Uint32
0
Uint16
0
Uint16
-2
Uint32
67
Uint16
-
Uint8
-
Uint8
-4
Uint32
-4
Uint32
-4
Uint32
-3
Uint32
0
Uint8
0
Uint16
67
Uint16
-1
Uint16
0
Uint16
0
Uint16
0
Int16
0
Int16
0
Int16
-2
Uint16
0
Uint16
-3
Uint8
-1
Uint16
-
Uint8
67
Uint16
-1
Uint16
-1
Uint8
-
Uint8
67
Uint16
-1
Uint16
67
Uint16
-1
Uint16
-
Uint8
-
Uint16
-