Download Inhoudsopgave Inhoud Print deze pagina

Danfoss VLT AutomationDrive FC 300 Programmeerhandleiding pagina 211

Verberg thumbnails Zie ook voor VLT AutomationDrive FC 300:
Inhoudsopgave

Advertenties

Parameterlijsten
4.1.22 32-** MCO basisinstell
Par.
Parameter description
No.
#
32-0* Encoder 2
32-00 Incrementeel signaaltype
32-01 Incrementele resolutie
4
4
32-02 Absoluut protocol
32-03 Absolute resolutie
32-04 Absolute Encoder Baudrate X55
32-05 Datalengte absolute encoder
32-06 Klokfrequentie absolute encoder
32-07 Klokgeneratie absolute encoder
32-08 Kabellengte absolute encoder
32-09 Encoderbewaking
32-10 Draairichting
32-11 Deler eenheid gebr.
32-12 Noemer eenheid gebr.
32-13 Enc.2 Control
32-14 Enc.2 node ID
32-15 Enc.2 CAN guard
32-3* Encoder 1
32-30 Incrementeel signaaltype
32-31 Incrementele resolutie
32-32 Absoluut protocol
32-33 Absolute resolutie
32-35 Datalengte absolute encoder
32-36 Klokfrequentie absolute encoder
32-37 Klokgeneratie absolute encoder
32-38 Kabellengte absolute encoder
32-39 Encoderbewaking
32-40 Encoderafsluiting
32-43 Enc.1 Control
32-44 Enc.1 node ID
32-45 Enc.1 CAN guard
32-5* Terugk.bron
32-50 Bron slave
32-51 MCO 302 slotactie
32-52 Source Master
32-6* PID-regelaar
32-60 Proportionele factor
32-61 Afleidingsfactor
32-62 Integrale factor
32-63 Grenswaarde voor integr. som
32-64 PID-bandbreedte
32-65 Snelheid voorwaartse koppeling
32-66 Versn. voorwaartse koppeling
32-67 Max. toegestane positiefout
32-68 Omgekeerd gedrag voor slave
32-69 Samplingtijd voor PID-regeling
32-70 Scantijd voor profielgenerator
32-71 Grootte van Control Window (insch.)
32-72 Grootte van Control Window (uitsch.)
210
FC 300 Programmeerhandleiding
Default value
[1] RS422 (5V TTL)
1024 N/A
[0] Geen
8192 N/A
[4] 9600
25 N/A
262.000 kHz
[1] Aan
0 m
[0] Uit
[1] Geen actie
1 N/A
1 N/A
[0] No soft changing
127 N/A
null
[1] RS422 (5V TTL)
1024 N/A
[0] Geen
8192 N/A
25 N/A
262.000 kHz
[1] Aan
0 m
[0] Uit
[1] Aan
[0] No soft changing
127 N/A
null
[2] Encoder 2
[1] Uitsch.
[1] Encoder 1 X56
30 N/A
0 N/A
0 N/A
1000 N/A
1000 N/A
0 N/A
0 N/A
20000 N/A
[0] Omkeren toegestaan
1 ms
1 ms
0 N/A
0 N/A
®
MG33MD10 – VLT
is een gedeponeerd handelsmerk van Danfoss
4-set-up
FC 302
Change
only
during
operation
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
All set-ups
FALSE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
Conver-
Type
sion
index
-
Uint8
0
Uint32
-
Uint8
0
Uint32
-
Uint8
0
Uint8
0
Uint32
-
Uint8
0
Uint16
-
Uint8
-
Uint8
0
Uint32
0
Uint32
-
Uint8
0
Uint8
-
Uint8
-
Uint8
0
Uint32
-
Uint8
0
Uint32
0
Uint8
0
Uint32
-
Uint8
0
Uint16
-
Uint8
-
Uint8
-
Uint8
0
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Uint32
0
Uint32
0
Uint32
0
Uint16
0
Uint16
0
Uint32
0
Uint32
0
Uint32
-
Uint8
-3
Uint16
-3
Uint8
0
Uint32
0
Uint32

Advertenties

Inhoudsopgave
loading

Inhoudsopgave