Parameterbeschrijving
10-11 Process Data Config Write
Selecteer de te schrijven procesgegevens voor I/O-constructie-
voorbeelden 101/151. De elementen [2] en [3] van deze array
kunnen worden geselecteerd. De elementen [0] en [1] van het
array liggen vast.
3
3
Option:
[593]
[595]
[597]
[653]
[663]
[673]
[683]
[748]
[890]
[891]
[1680]
[1682]
[1685]
[1686]
[3310]
[3311]
[3401]
[3402]
[3403]
[3404]
[3405]
[3406]
[3407]
[3408]
[3409]
[3410]
10-12 Process Data Config Read
Selecteer de proces-uitleesgegevens voor I/O-constructievoor-
beelden 101/151. De elementen [2] en [3] van deze array kunnen
worden geselecteerd. De elementen [0] en [1] van het array
liggen vast.
Option:
[0]
*
[15]
[1472]
[1473]
[1474]
[1500]
[1501]
[1502]
[1600]
[1601]
[1602]
[1603]
[1605]
[1609]
[1610]
126
FC 300 Programmeerhandleiding
Pulse Out #27 Bus Control
Pulse Out #29 Bus Control
Pulse Out #X30/6 Bus Control
Term 42 Output Bus Ctrl
Terminal X30/8 Bus Control
Terminal X45/1 Bus Control
Terminal X45/3 Bus Control
PCD Feed Forward
Bus Jog 1 Speed
Bus Jog 2 Speed
Fieldbus CTW 1
Fieldbus REF 1
FC Port CTW 1
FC Port REF 1
Sync Factor Master
Sync Factor Slave
PCD 1 Write to MCO
PCD 2 Write to MCO
PCD 3 Write to MCO
PCD 4 Write to MCO
PCD 5 Write to MCO
PCD 6 Write to MCO
PCD 7 Write to MCO
PCD 8 Write to MCO
PCD 9 Write to MCO
PCD 10 Write to MCO
None
Readout: actual setup
Legacy Alarm Word
Legacy Warning Word
Leg. Ext. Status Word
Operating Hours
Running Hours
kWh Counter
Control Word
Reference [Unit]
Reference %
Status Word
Main Actual Value [%]
Custom Readout
Power [kW]
MG33MD10 – VLT
10-12 Process Data Config Read
Selecteer de proces-uitleesgegevens voor I/O-constructievoor-
beelden 101/151. De elementen [2] en [3] van deze array kunnen
worden geselecteerd. De elementen [0] en [1] van het array
liggen vast.
Functie:
Option:
[1611]
[1612]
[1613]
[1614]
[1615]
[1616]
[1617]
[1618]
[1619]
[1620]
[1621]
[1622]
[1625]
[1630]
[1632]
[1633]
[1634]
[1635]
[1638]
[1639]
[1650]
[1651]
[1652]
[1653]
[1657]
[1660]
[1661]
[1662]
[1663]
[1664]
[1665]
[1666]
Functie:
[1667]
[1668]
[1669]
[1670]
[1671]
[1672]
[1673]
[1674]
[1675]
[1676]
[1677]
[1678]
[1679]
[1684]
[1690]
[1691]
®
is een gedeponeerd handelsmerk van Danfoss
Power [hp]
Motor Voltage
Frequency
Motor Current
Frequency [%]
Torque [Nm]
Speed [RPM]
Motor Thermal
KTY sensor temperature
Motor Angle
Torque [%] High Res.
Torque [%]
Torque [Nm] High
DC Link Voltage
Brake Energy /s
Brake Energy /2 min
Heatsink Temp.
Inverter Thermal
SL Controller State
Control Card Temp.
External Reference
Pulse Reference
Feedback [Unit]
Digi Pot Reference
Feedback [RPM]
Digital Input
Terminal 53 Switch Setting
Analog Input 53
Terminal 54 Switch Setting
Analog Input 54
Analog Output 42 [mA]
Digital Output [bin]
Freq. Input #29 [Hz]
Freq. Input #33 [Hz]
Pulse Output #27 [Hz]
Pulse Output #29 [Hz]
Relay Output [bin]
Counter A
Counter B
Prec. Stop Counter
Analog In X30/11
Analog In X30/12
Analog Out X30/8 [mA]
Analog Out X45/1 [mA]
Analog Out X45/3 [mA]
Comm. Option STW
Alarm Word
Alarm Word 2
Functie: