Parameterbeschrijving
9-23 Parameters for Signals
Array [1000]
Alleen lezen
Option:
[1671] Relay Output [bin]
[1672] Counter A
[1673] Counter B
[1674] Prec. Stop Counter
[1675] Analog In X30/11
[1676] Analog In X30/12
[1677] Analog Out X30/8 [mA]
[1678] Analog Out X45/1 [mA]
[1679] Analog Out X45/3 [mA]
[1680] Fieldbus CTW 1
[1682] Fieldbus REF 1
[1684] Comm. Option STW
[1685] FC Port CTW 1
[1686] FC Port REF 1
[1690] Alarm Word
[1691] Alarm Word 2
[1692] Warning Word
[1693] Warning Word 2
[1694] Ext. Status Word
[1860] Digital Input 2
[3310] Sync Factor Master
[3311] Sync Factor Slave
[3401] PCD 1 Write to MCO
[3402] PCD 2 Write to MCO
[3403] PCD 3 Write to MCO
[3404] PCD 4 Write to MCO
[3405] PCD 5 Write to MCO
[3406] PCD 6 Write to MCO
[3407] PCD 7 Write to MCO
[3408] PCD 8 Write to MCO
[3409] PCD 9 Write to MCO
[3410] PCD 10 Write to MCO
[3421] PCD 1 Read from MCO
[3422] PCD 2 Read from MCO
[3423] PCD 3 Read from MCO
[3424] PCD 4 Read from MCO
[3425] PCD 5 Read from MCO
[3426] PCD 6 Read from MCO
[3427] PCD 7 Read from MCO
[3428] PCD 8 Read from MCO
[3429] PCD 9 Read from MCO
[3430] PCD 10 Read from MCO
[3440] Digital Inputs
[3441] Digital Outputs
[3450] Actual Position
[3451] Commanded Position
[3452] Actual Master Position
[3453] Slave Index Position
[3454] Master Index Position
[3455] Curve Position
FC 300 Programmeerhandleiding
Functie:
®
MG33MD10 – VLT
is een gedeponeerd handelsmerk van Danfoss
9-23 Parameters for Signals
Array [1000]
Alleen lezen
Option:
[3456] Track Error
[3457] Synchronizing Error
[3458] Actual Velocity
[3459] Actual Master Velocity
[3460] Synchronizing Status
[3461] Axis Status
[3462] Program Status
[3464] MCO 302 Status
[3465] MCO 302 Control
[3470] MCO Alarm Word 1
[3471] MCO Alarm Word 2
[4280] Safe Option Status
[4285] Active Safe Func.
[4286] Safe Option Info
9-27 Parameter Edit
Option:
Functie:
Parameters kunnen worden gewijzigd via
Profibus, de standaard RS 485-interface, of het
LCP.
[0]
Disabled Schakelt het wijzigen via Profibus uit.
[1]
Enabled Schakelt het wijzigen via Profibus in.
*
9-28 Process Control
Option:
Functie:
Procesregeling (instellen van stuurwoord,
snelheidsreferentie en procesdata) is mogelijk
via Profibus of de standaard veldbus, maar niet
via beide tegelijkertijd. Lokale besturing is altijd
mogelijk via het LCP. Besturing via procesre-
geling is mogelijk via de klemmen of de
veldbus, afhankelijk van de instellingen in
8-50 Coasting Select tot 8-56 Preset Reference
Select.
[0]
Disable
Schakelt de procesregeling via Profibus uit en
schakelt procesregeling via een standaard
veldbus of Profibus-master klasse 2 in.
[1]
Enable
Schakelt de procesregeling via Profibus-master
*
cyclic
klasse 1 in en schakelt procesregeling via een
master
standaard veldbus of Profibus-master klasse 2
uit.
9-44 Fault Message Counter
Range:
Functie:
0
[0 - 65535 ] Deze parameter geeft het aantal foutgebeurte-
*
nissen aan dat is opgeslagen in 9-45 Fault Code
en 9-47 Fault Number. De maximale buffercapa-
citeit is acht foutgebeurtenissen. Buffer en