Download Inhoudsopgave Inhoud Print deze pagina

Danfoss VLT AutomationDrive FC 300 Programmeerhandleiding pagina 207

Verberg thumbnails Zie ook voor VLT AutomationDrive FC 300:
Inhoudsopgave

Advertenties

Parameterlijsten
4.1.18 16-** Data-uitlezingen
Par.
Parameter description
No.
#
16-0* Alg. status
16-00 Stuurwoord
4
4
16-01 Referentie [Eenh.]
16-02 Referentie %
16-03 Statuswoord
16-05 Vrnste huid. waarde [%]
16-09 Standaard uitlez.
16-1* Motorstatus
16-10 Verm. [kW]
16-11 Verm. [pk]
16-12 Motorspanning
16-13 Frequentie
16-14 Motorstroom
16-15 Frequentie [%]
16-16 Koppel [Nm]
16-17 Snelh. [RPM]
16-18 Motor therm.
16-19 KTY-sensortemperatuur
16-20 Motorhoek
16-21 Torque [%] High Res.
16-22 Koppel [%]
16-25 Koppel [Nm] hoog
16-3* Status omvormer
16-30 DC-aansluitsp.
16-32 Remenergie/s
16-33 Remenergie/2 min.
16-34 Temp. koellich.
16-35 Inverter therm.
16-36 Geïnv. nom. stroom
16-37 Geïnv. max. ingangsstr.
16-38 SL-controllerstatus
16-39 Temp. stuurkaart
16-40 Logbuffer vol
16-41 LCP onderste statusreg
16-49 Current Fault Source
16-5* Ref. & terugk.
16-50 Externe referentie
16-51 Pulsreferentie
16-52 Terugk. [Eenh]
16-53 Digi Pot referentie
16-57 Feedback [RPM]
16-6* In- & uitgangen
16-60 Dig. ingang
16-61 Klem 53 schakelinstell.
16-62 Anal. ingang 53
16-63 Klem 54 schakelinstell.
206
FC 300 Programmeerhandleiding
Default value
0 N/A
0.000 ReferenceFeed-
backUnit
0.0 %
0 N/A
0.00 %
0.00 CustomReadoutUnit
0.00 kW
0.00 hp
0.0 V
0.0 Hz
0.00 A
0.00 %
0.0 Nm
0 RPM
0 %
0 °C
0 N/A
0.0 %
0 %
0.0 Nm
0 V
0.000 kW
0.000 kW
0 °C
0 %
ExpressionLimit
ExpressionLimit
0 N/A
0 °C
[0] Nee
0 N/A
0 N/A
0.0 N/A
0.0 N/A
0.000 ReferenceFeed-
backUnit
0.00 N/A
0 RPM
0 N/A
[0] Stroom
0.000 N/A
[0] Stroom
®
MG33MD10 – VLT
is een gedeponeerd handelsmerk van Danfoss
4-set-up
FC 302
Change
only
during
operation
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
x
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
Conver-
Type
sion
index
0
V2
-3
Int32
-1
Int16
0
V2
-2
N2
-2
Int32
1
Int32
-2
Int32
-1
Uint16
-1
Uint16
-2
Int32
-2
N2
-1
Int16
67
Int32
0
Uint8
100
Int16
0
Uint16
-1
Int16
0
Int16
-1
Int32
0
Uint16
0
Uint32
0
Uint32
100
Uint8
0
Uint8
-2
Uint32
-2
Uint32
0
Uint8
100
Uint8
-
Uint8
VisStr[50
0
]
0
Uint8
-1
Int16
-1
Int16
-3
Int32
-2
Int16
67
Int32
0
Uint16
-
Uint8
-3
Int32
-
Uint8