SAMENGESTELDE ACCU VOEDING VAN
DOOR VERBINDINGSONDERDEEL
GELEVERDE UITRUSTING
AFSLUITING VAN
DE
HULPVERTRAGING
HULP DIRECTE
AFSLUITING
WEERSTAND
120 OM
UNINS
–
ONGEISOLEERDE
RED – ROOD
BLK – ZWART
WHT – WIT
GRN – GROEN
YEL – GEEL
AM – AM – WISSELSTROOM AMPÈREMETER.
AVR – AUTOMATISCHE SPANNINGSREGULATOR.
BCA – ACCUOPLADER WISSELSTROOMINSTELLING
BV – VOLTMETER VAN DE ACCU.
CMB - COMMUNICATIE MODULE BOORD
CT (#) – STROOM TRANSFORMATOR.
CTG – METER KOELMIDDELTEMPERATUUR.
CTS – ZENDER KOELMIDDEL EMPERATUUR
D (#) – DIODE
ECM – MOTORCONTROLEMODULE
ESS – NOODSTOPSCHAKELAAR
ETS – SCHAKELAAR UITLAATTEMPERATUUR
FLA – BRANDSTOFLEKALARM
HR – UURMETER
Figuur 7-43 55-99EOZD/40-80EFOZD Schematisch, Dec 3+ controlesysteem, Geïsoleerde aarde, Blad 1 van 1 (ADV7250-A)
TP-6441-NL 11/06
(ISOCHRONE BEHEERSER)
(SECUNDAIRE ANALOGE GASPEDAAL)
(TERUGKEER VAN DE SENSOR)
(GESCHAKELDE VOEDING)
(SAMENGESTELDE ACCU VOEDING)
(ACCUVOEDING NAAR ECM)
(AANDRIJVER
WAARSCHUWINGSLAMP)
KUN 55-99 KW
(OPHEFFING VAN DE AFSLUITING)
(TERUGKEER VAN DE OPHEFFING VAN DE
AFSLUITING)
(ONTSTEKING VAN DE
WISSELSTROOMINSTELLING)
(KAN HOOG)
(KAN LAAG)
(KAN BESCHERMING)
AARDEVERBINDING VAN HET
SYSTEEM VAN DOOR
VERBINDINGSONDERDEEL
GELEVERDE UITRUSTING
12 VDC ACCU
12 VDC ACCU
(ALLEEN
GEBRUIKT VOOR
24V)
CONTROLESYSTEEMBOO
AARDE
P1-12-NAAR: ZEKERING #1
ZEKERING #2
ZEKERING #3
ACCUSPANNING
(ZEKERING 3))
VOORKOM VOOR 30
SECONDEN NA START,
DAN 5 SECONDEN
ACCUSPANNING
(ZEKERING 3))
AFSLUITING
ACCUSPANNING
(ZEKERING 3)
MESSA A TIERRA
AARDE
PREALARM
ZWENGEL ONTBINDING
OVERCRANK
BLOKKEER ROTOR
TE HOGE SNELHEID
AUTOMATISCHE HERSTART
+12VDC GEREGULEERD (ZEKERING
#2)
AARDE
AARDE VAN HET SCHILD
WISSELSTROOM
ZWENGEL
ONTBINDING
NAARAN STAT [FRII] ZIE
HOGE
ACCUSPANNING
NAARAN STAT [FRII] ZIE
NAARAN STAT [FRII] ZIE
HZ – FREQUENTIEMETER
IPA - INDICATORPANEEL ASSEMBLAGE
K11 – ECM CONTROLERELAIS
K20 – AANZWENGELRELAIS
LCL – SCHAKELAAR LAAG KOELMIDDELNIVEAU
LCT – SCHAKELAAR LAGE
KOELMIDDELTEMPERATUUR
LOL – SCHAKELAAR LAAG OLIENIVEAU.
LWP – LAGE ZEEWATERDRUK.
MSLL – LAGERE SCHAALMETERLAMP
MSLU – HOGERE SCHAALMETERLAMP.
OPG – OLIEDRUKMETER
OPS – OLIEDRUKZENDER
WEERSTAND
510 OM
ALLEEN 125-180 KW
ALLEEN 55-99 KW
NAARAVR (P5) [FRII] ZIE
adv-6955
ALLEEN 12V
KUN 12 V
FACULTATIEF
(
)
ADV-6955
ADV-6955
ADV-6955
LEGENDA
P (#) - STIK
PL (#) – INDIKATOR PÅ PANEL
SELSW – KEUZESCHAKELAAR
SFG – VEILIGHEIDSONDERBREKER
SM – ELEKTROMOTOR FOR STARTER
SM – STARTER VAN DE MOTOR.
TB1, 2 – CONTROLESYSTEEMBOORD TERMINAL
BLOK
TB3 – STROOMTRANSFORMATOR/SCHAALMETER
TERMINAL BLOK.
TB4 – WISSELSTROOMZEKERING TERMINAL BLOK.
TB11 – VEILIGHEIDSONDERBREKER TERMINALBLOK
TB12 - TERMINAL BLOK VSG
VADJ – SPANNINGSAANPASSING.
VM – VOLTMETER
TERMINAL IDENTIFICATIE
42A ACCUSPANNING (ZEKERING #1 BESCHERMD).
2 AARDING
3 AARDING START OP AFSTAND.
4 START OP AFSTAND (ACTIEF LAAG).
WEERSTAND
9
AANZWENGEL
REGIME
4,7 OM
GESLOTEN = ONONDERBROKEN).
9A AARDING AANZWENGEL REGIME.
12 OVERCRANK INDICATOR.
24 +12VDC GEREGULEERDE.
26 HULPINDICATOR
32
ALGEMENE
FOUTMELDING/PRE-ALARM
(GEACTIVEERD DOOR HET, PHET, LOP, PLOP, OS, LWT,
OC, LF, HULPFOUTMELDINGEN).
32A ALGEMENE FOUTMELDING LIJN 2 (GEACTIVEERD DOOR
NOODSTOP, OS, LOP, HET, HULPFOUTMELDINGEN).
36 INDICATOR HOGE MOTORTEMPERATUUR.
38 INDICATOR LAGE OLIEDRUK.
WEERSTAND
39 INDICATOR TE HOGE SNELHEID.
510 OM
43 UIT/HERINSTELLINGS COMMANDO (ACTIEF LAAG).
46 AUTO COMMANDO (ACTIEF LAAG).
WEERSTAND
47 AAN COMMANDO (ACTIEF LAAG).
4,7 OM
56 INDICATOR LUCHTDEMPER.
60 SYSTEEM KLAAR INDICATOR.
70C GENERATOR IN AFKOELINGSTOESTAND.
70R GENERATOR AAN.
80 NIET IN AUTOMATISCH INDICATOR.
36 HULPPREALARM – BEPAALD DOOR DE
GEBRUIKER.
BASSA TEMPERATURA DELL'ACQUA
40 LAGE WATERTEMPERATUUR.
41
PREALARM
MOTORTEMPERATUUR.
*1 PREALARM INDICATOR LAGE OLIEDRUK.
*1A NOODSTOP RELAIS (K4) AARDE.
27 NOODSTOP RELAIS (K4) SPOEL, NEGATIEF.
48 NOODSTOP INDICATOR.
CONTACTEN GETOOND MET
61 OPLADERSFOUTMELDING VAN DE ACCU
SCHAKELAAR IN OFF-POSITIE
(ACTIEF LAAG).
62 LAGE ACCU VOLTS (ACTIEF LAAG).
63 LAGE BRANDSTOF (ACTIEF LAAG).
* MOET VERBINDINGSDRAAD HEBBEN ALS ER
GEEN NOODSTOPUITRUSTING VERBONDEN IS.
1P HOOFDVOEDING OPERATIE.
2P HOOFDVOEDING OPERATIE.
3P HOOFDVOEDING OPERATIE.
4P HOOFDVOEDING OPERATIE.
OPMERKING
DE SPATIE DUIDT OPEN CONTACT AAN
OPMERKING
„C" DUIDT GESLOTEN CONTACT AAN
STROOMTRANSFORMAT
„M" DUIDT AAN MAAKT VÓÓR ONDERBREKING VAN HET CONTACT
ORDRADEN GAAN
RECHTSTREEKS NAAR
TB11 WANNEER DE
VEILIGHEIDSONDERBRE
KER NIET WORDT
GEBRUIKT
OPMERKING
STROOMTRANSFORMATOR
PUNT OF „H1" NAAR DE
GENERATOR
OPMERKING
DE SPATIE DUIDT OPEN CONTACT AAN
„C" DUIDT GESLOTEN CONTACT AAN
„M" DUIDT AAN MAAKT VÓÓR ONDERBREKING VAN HET
CONTACT
TERUGKEER VAN DE OLIEDRUK
SIGNAAL VAN DE OLIEDRUK
TERUGKEER VAN DE
KOELMIDDELTEMPERATUUR
SIGNAAL VAN DE
KOELMIDDELTEMPERATUUR
AARDE VAN HET MOTORBLOK
Hoofdstuk 7 Bedradingsschema's
OMSCHRIJVING.
(OPEN
=
CYCLISCH;
LIJN
1
CONTROLLER
STANDARD
STANDAARD
STANDARD
CONTROLLER
CONTROLESYSTEE
M
VEREIST
PREALARM-
UITRUSTING OM TE
WERKEN.
INDICATOR
HOGE
GEBRUIKT
VOOR DE
TOEBEHOREN
VAN DECISION
MAKER 3+.
VEREIST
FACULTATIEVE
UITRUSTING.
225