Download Print deze pagina

Victron energy Cerbo GX Handleiding pagina 130

Verberg thumbnails Zie ook voor Cerbo GX:

Advertenties

'Devices/00002CC001F4/Nad': 149,
'Devices/00002CC001F4/Serial': '0000500',
'Devices/00002CC005EA/CustomName': 'Hub-1',
'Devices/00002CC005EA/DeviceInstance': 0,
'Devices/00002CC005EA/FirmwareVersion': 'v2.60-beta-29',
'Devices/00002CC005EA/Manufacturer': 358,
'Devices/00002CC005EA/ModelName': 'Color Control GX',
'Devices/00002CC005EA/N2kUniqueNumber': 1514,
'Devices/00002CC005EA/Nad': 11,
'Devices/00002CC005EA/Serial': '0001514',
'Devices/00002CC005EB/CustomName': 'SmartBMV',
[and so forth]
Voer, om ze te wijzigen, een SetValue oproep uit op het DeviceInstance-pad zoals onderaan. Of, misschien eenvoudiger nog,
gebruik de dbus-spy tool.
Deze lijnen lezen het, wijzigen het dan naar 1, lezen het dan opnieuw:
root@ccgx:~# dbus -y com.victronenergy.vecan.can0 /Devices/00002CC005EB/DeviceInstance GetValue
value = 0
root@ccgx:~# dbus -y com.victronenergy.vecan.can0 /Devices/00002CC005EB/DeviceInstance SetValue %1
retval = 0
root@ccgx:~# dbus -y com.victronenergy.vecan.can0 /Devices/00002CC005EB/DeviceInstance GetValue
value = 1
[note that numbers, like can0, and 00002CC005EB can ofcourse be different on your system].
Nieuwe methode - wijzigen van Data instance:
Dit is alleen van toepassing op de NMEA2000-uit functie.
De Data instances die worden gebruikt voor de NMEA2000-out functie zijn opgeslagen in lokale instellingen. Hier is een fragment
van de regels, genomen met behulp van het dbus-spy hulpprogramma waarmee ook gegevens gewijzigd kunnen worden (de
Data-instances zijn de instances "Battery-", "DC Detailed-", enzovoort):
Settings/Vecan/can0/Forward/battery/256/BatteryInstance0
Settings/Vecan/can0/Forward/battery/256/BatteryInstance1
Settings/Vecan/can0/Forward/battery/256/Description2
Settings/Vecan/can0/Forward/battery/256/IdentityNumber
Settings/Vecan/can0/Forward/battery/256/Instance
Settings/Vecan/can0/Forward/battery/256/Nad
Settings/Vecan/can0/Forward/battery/256/SwitchInstance1
Settings/Vecan/can0/Forward/battery/256/SystemInstance
Settings/Vecan/can0/Forward/solarcharger/0/DcDataInstance0
Settings/Vecan/can0/Forward/solarcharger/0/DcDataInstance1
Settings/Vecan/can0/Forward/solarcharger/0/Description2
Settings/Vecan/can0/Forward/solarcharger/0/IdentityNumber
Settings/Vecan/can0/Forward/solarcharger/0/Instance
Settings/Vecan/can0/Forward/solarcharger/0/Nad
Settings/Vecan/can0/Forward/solarcharger/0/SystemInsta
Settings/Vecan/can0/Forward/solarcharger/1/DcDataInstance0
Settings/Vecan/can0/Forward/solarcharger/1/DcDataInstance1
Settings/Vecan/can0/Forward/solarcharger/1/Description2
Settings/Vecan/can0/Forward/solarcharger/1/IdentityNumber
Settings/Vecan/can0/Forward/solarcharger/1/Instance
Settings/Vecan/can0/Forward/solarcharger/1/Nad
Settings/Vecan/can0/Forward/solarcharger/1/SystemInstance
Settings/Vecan/can0/Forward/solarcharger/258/DcDataInstance0
Settings/Vecan/can0/Forward/solarcharger/258/DcDataInstance1
Settings/Vecan/can0/Forward/solarcharger/258/Description2
Settings/Vecan/can0/Forward/solarcharger/258/IdentityNumber
Settings/Vecan/can0/Forward/solarcharger/258/Instance
Settings/Vecan/can0/Forward/solarcharger/258/Nad
Settings/Vecan/can0/Forward/solarcharger/258/SystemInstance
Oude methode:
1.
Vermeld de apparaten:
root@ccgx:~# dbus -y
com.victronenergy.bms.socketcan_can0_di0_uc10
com.victronenergy.charger.socketcan_can0_di1_uc12983
Pagina 124
Cerbo GX Handleiding
15
233
25
36
24
36
23
36
0
<- Data instance for main voltage measur
1
<- Data instance for starter or mid-volt
1
<- Source address - no need, also not go
0
<- Data instance for switchbank
0
0
1
0
0
0
<- Battery voltage & current
1
<- PV voltage & current
0
0
0
1
0
0
Integratie Maritieme MFD's met
NMEA 2000

Advertenties

loading