Download Print deze pagina

Abus FUAA80000 Installatiehandleiding pagina 64

Advertenties

6.8. ABUS Cloud
The Comfion wireless security system connects to the Abus Cloud during initial commissioning. The system is also stored
in the installer's Abus Cloud installer account. If this is not desired, the "Main installer" checkbox can be removed under
the respective user in the system, or can also be set for another installer.
6.9. Notes on the hard drive
The screws for fastening the hard drive must only be tightened by hand
The battery life of the control panel depends, among other things, on the hard drive installed and its power
consumption, as well as the number of cameras and the selected recording type (continuous recording, etc.).
The hard drive installed in the Comfion must be formatted in exFAT or NTFS format
Only replace the hard drive when the control panel is de-energised
6.10.
Service and maintenance by installers
Test that the system is working properly during routine maintenance:
Check the Comfion system for obvious signs of damage to the housing or front cover.
Check the action of the tamper switches (wall tear-off/housing cover left, housing cover right)
Check the condition of the backup battery
Clean the housing
To clean, please wipe the surface with a soft, dry cloth.
o
Do not use any water, solvents or cleaning agents.
o
Check the signal strength and battery/rechargeable battery status of all components
Replace the batteries as recommended by the manufacturer
Test every component.
Carefully clean the lenses on all PIR detectors and cameras using a soft, clean, dry cloth.
Do not use any water, solvents or cleaning agents.
o
Carry out a walk test of all detectors.
Test all sounders
Test the communication.
ABUS recommends changing the system battery after a maximum of 3 years. A sudden drop in
Note
performance cannot be ruled out with longer running times.
How to change the control panel battery:
Set the alarm panel to maintenance mode (security settings)
Open the left housing cover
Disconnect the power supply and the old battery from the control panel
Wait for 30 seconds
Reconnect the new battery and the power supply
Close the cover of the system and then exit maintenance mode again
6.11.
Radio signal strength table
The following table describes the meaning of the signal values of the Comfion radio components displayed in dBm.
RSSI-value (dBm)
<= -100
<= -96
<= -91
<= -86
> -86
Meaning
Poor
OK
Good
Very good
excellent
Display at the device
0 bars
1 bars
2 bars
3 bars
4 bars
|31

Advertenties

loading