6.1.3. Security Settings
Zone lock
Keypad Retry Max
Keypad Timeout
Entry Delay
Exit Delay
Transmission delay
Power Loss Report Delay
Enable Intruder siren
Intruder Siren Duration
Enable Tamper Siren
Tamper Siren Duration
Enable Panic Siren
Panic Siren Duration
Enable Flood Siren
Flood Siren Duration
Enable Smoke Siren
Smoke Siren Duration
Enable SOS Siren
SOS Siren Duration
Fault Override Network
Fault Override Battery
Fault Override AC Lost
Fault Override Tamper SATA
Fault Override Tamper Case
Maintenance
3x-20x
If a zone is triggered more often than set, this
(Default 5x)
zone will no longer trigger until the alarms are
deleted from the alarm history
3x-20x
Indicates after how many incorrect PIN entries
(Default 5x)
on the control panel it is locked
5-180 sec
Time setting for how long the control panel is
(Default 30 sec)
locked after X incorrect entries
5-45 sec
If the system is armed, the input delay is
(Default 10 sec)
triggered by an input or input/output zone
5-45 sec
Time before the control centre changes to the
(Default 30 sec)
armed state
5-180 sec
If this feature is activated in the zone, the
(Default 60 sec)
transmission of a trigger is delayed by the set
time.
0-30 min
Adjustable delay for signalling a loss of voltage
(Default 0 min)
(12V DC)
On/OFF
Siren activation in the event of a burglar alarm
(Default AN)
5-180 sec
Duration of acoustic signalling by sirens
(Default 60 sec)
integrated into the system
On/OFF
Siren activation in the event of a tamper alarm
(Default AN)
5-180 sec
Duration of acoustic signalling by sirens
(Default 60 sec)
integrated into the system
On/OFF
Siren activation in the event of a hold-up alarm
(Default OFF)
5-180 sec
Duration of acoustic signalling by sirens
(Default 60 sec)
integrated into the system
On/OFF
Siren activation in the event of a water alarm
(Default AN)
5-180 sec
Duration of acoustic signalling by sirens
(Default 60 sec)
integrated into the system
On/OFF
Siren activation in the event of a fire alarm
(Default AN)
5-180 sec
Duration of acoustic signalling by sirens
(Default 60 sec)
integrated into the system
On/OFF
Siren activation in the event of a Panic alarm
(Default OFF)
triggered via the app
5-180 sec
Duration of acoustic signalling by sirens
(Default 60 sec)
integrated into the system
On/OFF
Detection and reporting of a network error
(Default OFF)
On/OFF
Detection and signalling of a battery fault
(Default OFF)
On/OFF
Detection and signalling of power loss (12V DC)
(Default OFF)
On/OFF
Detection and signalling of sabotage of the
(Default OFF)
right-hand cover (hard drive)
On/OFF
Detection and signalling of sabotage of the left
(Default OFF)
cover (battery)
On/OFF
Maintenance mode is used to install and
(Default OFF)
maintain the system. The system cannot trigger
any alarms while maintenance mode is active.
|23