Short Instruction
The pump is driven by a DC-motor and, therefore, equipped with a controller. Check the following sequence when starting the pump:
1. Flush the pump thoroughly to remove any residual disinfection fluids!
2. Install the pump below the water surface (Pump is not self-priming).
3. Interconnect pump and controller using the attached controller cable (check pins).
4. Check the main power switch is set to „0" (OFF).
5. Connect the mains cable to the controller and plug into a wall plug.
6. Switch on the controllers power switch.
7. Press the RUN button (pump will start after a 10 seconds delay)
Coded plug, fits only one way
Key
Function
Switching the pump on and off
RUN: to start the pump
STOP: to stop the pump
Increase pump power (when running):
Higher flow-rate, more energy consumpion
Decrease pump power (when running):
lower flow-rate, less energy consumpion
After switching on there is a 10 second delay countdown. After that, the pump slowly increases speed to the previous value set, while
the flow rate is also updated. When switched off, the pump stops immediately.
0-10V connector
Controller cable
Power cable 230 V
Fuse
Power Switch