General operation

Operation and function of the display.
Attention:
The imprint on buttons and display may differ from the text in the manual, but the functions remain the same.
Buttons & Display
1
4
5
2
3
LCD Display
1
2
3
The external connection with RJ45 connector can be used to change the RPM. A 10volt signal triggers the maximum RPM (±2800).
Please note: the 0-10volt signal cannot trigger a RPM setting lower than the current value. Example: the pump is running at 1500 RPM
and the 0-10v connector sends out a low voltage that is below the 1500 RPM, nothing will happen. The moment the outgoing signal is
higher than the 1500RPM, the 1500 RPM will increase. Use pin 2 and 5 of the RJ45 connector.
1
LCD Display
2
Run LED: This led is on during pump performance
3
Stop LED: This led is on when the pump has stopped
4
Increases the RPM
5
Decreases the RPM
The display shows the following data:
1
Hour counter: shows how many hours the pump has been running
2
Wattage: the current energy consumption
4
3
RPM (Rotations Per Minute).
4
Amperage