Blue Eco Manual | English
Timer B settings
Display text
Adjustable values
00:00 – 23:59/23:59:50/24:00:00
Start time
(Default 12:00)
300 – 2100/3400 RPM
Set Speed 1
(Default 1500.RPM)
00:00 – 23:59/23:59:50/24:00:00
Middle Time 1
(Default 13:00)
0 – 3000 RPM (Default 1500.RPM)
Set Speed 2
00:00 – 23:59/23:59:50/24:00:00
Middle Time 2
(Default 14:00)
0 – 2100/3400 RPM (Default 1500.
Set speed 3
RPM)
00:00 – 23:59/23:59:50/24:00:00
Middle time 3
(Default 15:00)
0 – 2100/3400 RPM (Default 1500.
Set Speed 4
RPM)
00:00 – 23:59/23:59:50/24:00:00
Stop Time
(Default 16:00)
Disable/Enable (Default Disable)
Repeat enable
Notes:
1. The timer cannot extend beyond midnight. Start no earlier than 00:00 and stop no later than 23:59/23:59:50/24:00:00.
2. The set times must be sequential. Otherwise, when the timer is selected and 'RUN' is pressed the display will show 'ALERT TIMER SET
ERROR'.
Description
Start time for timer B.
The pump runs at this speed until the next time 1.
Pump changes speed when the set time is reached.
Pump now runs at this speed until the next set time. If a speed
between 0 and 300 is selected, the pump automatically switches to
300 rpm.
Pump runs at new speed until the next set time is reached.
Pump now runs at this speed from set time 2 to set time 3. If a
speed between 0 and 300 is selected, the pump automatically
switches to 300 rpm.
Pump changes speed at the set time.
Pump now runs at this speed from set time 3 to the stop time. If
a speed between 0 and 300 is selected, the pump automatically
switches to 300 rpm.
Pump stops at the set time the next day. If repetition is turned
off, the pump will switch back to manual mode at the end of the
cycle.
This setting specifies whether you want to continuously repeat
timer A. Disable = one time. Enable = repeat.