Boiler heating timeout: the boiler has
ER04
not heated within the maximum time
expected. Boiler heating is disabled
Tank probe open:
ER05
the tank temperature probe is not
connected or is it interrupted.
Tank heating is disabled
Tank probe short-circuited:
ER06
the tank temperature probe has
shorted.
Tank heating is disabled
Boiler probe open:
ER07
the boiler temperature probe is not
connected or is it interrupted.
Boiler heating is disabled
Boiler probe short-circuited:
ER08
the boiler temperature probe has
shorted.
Boiler heating is disabled
Tank safety thermostat:
ER09
the tank safety thermostat has inter-
vened
Boiler safety thermostat:
ER10
the boiler safety thermostat has inter-
vened
Thermostop timeout:
ER11
the boiler has not reached the tem-
perature set during the thermostop
phase. Boiler heating is disabled.
Drain timeout:
ER12
the tank pressure switch did not open
at the end of the manual drain cycle
Panel disconnected:
ER14
the panel was disconnected during
machine operation and therefore it
is no longer controllable by the key-
board
Overflow tube inserted incorrectly.
If the problem persists, request technical
assistance
Request the intervention of a technician
Request the intervention of a technician
Request the intervention of a technician
Request the intervention of a technician
Request the intervention of a technician
Request the intervention of a technician
Switch the dishwasher off and back on
again; if the problem occurs again, call
for technical assistance
Make sure that the overflow has been
removed from its seat and start an
additional drain cycle. If the alarm
persists, request technical assistance.
CAUTION RISK OF HOT WATER
Request the intervention of a technician