PROBLEM
EN
34
POSSIBLE CAUSE
Water supply pressure.
pressure is less than 1.5 bar
Water supply valve filter
clogged
The nozzles of the rotor are blocked.
The rotor arms do not turn
freely
Excessive rinse aid has caused this
foaming
Soaking of the dishes with unsuitable
detergent
The washing arms of the rotor (fig.
18) knock the parts to be washed
protruding from the basket
The rotor needs cleaning
The drain pipe (fig. 21) is blocked or
compressed
The drain pump filter (if
supplied – fig. 21) is clogged
The pump does not drain properly
The drain cycle does not start (only if
drain pump installed)
SOLUTION
Contact
an
supplementary pump to increase the
supply water pressure
Clean and rinse the water supply valve
filter
Wash and rinse the nozzles of the rotor.
- Position the dishes so that they are not
struck by the washing arms of the rotor,
following the instructions in para. 3.4
– PART TWO
- Wash and rinse the rotor.
Contact the installer to reduce the
amount of rinse aid.
Avoid soaking with foaming detergents
Place the dishes so that they do not
become hit by the washing arms of the
rotor by following the instructions in para.
3.4
– PART TWO
Wash and rinse the rotor
Remove the blockage from the drain
pipe
Wash and rinse the drain pipe filter.
Contact the installer to reduce the
replacement of the drain pump
Make sure the dishwasher door is closed
properly and clean the touch display
34
installer
to
install
a