8.6
CHIMNEY POT
EN
The chimney pot is important for the correct running of the heating appliance:
• We recommend using an anti-wind chimney pot, see Fig. 4 page 8.
• The hole width for fumes exhaust must be the double of the chimney flue width and fitted in a way that the
fume exhaust is assured also in case of wind.
• It should prevent the infiltration of rain, snow and animals.
• The outlet height in the atmosphere must be away from the reflux area caused by the roof structure or by
obstacles laying nearby (see Fig. 2 page 6).
8.7
CHIMNEY COMPONENTS
8
Fig. 4 - Anti-wind chimney pots
Fig. 5 - Chimney components
LEGEND
Fig. 5 page 8
1
Chimney pot
2
Fume outlet
3
Chimney flue
4
Termal insulation
5
External wall
6
Chimney union
7
Fume pipe
8
Heat generator
9
Inspection door
10
T-union with inspection plug