• Press P5: the display shows "SUNDAY PROG-1", with P1 and P2 keys set "ON" or "OFF".
Now press P5 and repeat all the previous instructions for Prog-2, Prog-3, Prog-4.
• To exit press three times P4.
EN
11.16
FAN ADJUSTMENT
Press P3 button in menu 1 "FAN ADJUST": the fan menus no.2 and no.3 will open.
Press P1 to adjust fan no. 2, while P2 button adjusts fan no. 3.
Function "A" activates the default fan data. (For example: heat output 1 activates default rotations at heat
output 1, heat output 2 activates default rotations at heat output 2, etc.).
With function "1" or "2" or "3" or "4" or "5" the fan is forced to work at the selected output. (For example: by
setting "2", even if the fan is set to heat output 5 it will work as if set to heat output "2", etc.).
11.17
FIRE EXTINGUISHING IN CASE OF FIRE
In case it would be necessary to extinguish the fire emitted by the stove or by the chimney flue, use a fire-
extinguisher or contact the firemen. DO NOT use water to extinguish the fire inside the burning pot.
11.18
PELLET SUPPLY
Fig. 37 - Wrong opening of the pellets bag
It is necessary to avoid to fill the hopper with the pellet when the stove is running.
• Do not get the bag of pellet in contact with hot stove surfaces.
• Do not empty the hopper with remaining fuels (unburnt pellet) from the burning pot coming from ignition
waster.
11.19
REMOTE CONTROL
The stove can be operated through a remote control.
24
If the stove is set to maximum heat output 5 and the fans to minimum output 1, this may
cause overheating and the "THERMAL SAFETY" alarm to go off.
The pellet hopper must always be closed with its own lid.
Fig. 38 - Right opening of the pellets bag
VENUS PLUS - GIOIA-2