10.3
GENERAL INSTALLATION
• Please check that the floor has an adequate load capacity. If the existing one does not satisfy this requirement,
appropriate measure should be provided (for example a plate for distributing the load).
• It is obligatory to install the stove away from walls and/or pieces of furniture, with a minimum air flow of 300
mm on the sides and 300 mm on the back, to enable an eficient appliance cooling and a good distribution
of heat in the room (see Fig. 12 page 13).
• For safety fire regulations the distances from flammable or sensible to heat objects (sofas, pieces of furniture,
wooden covering, etc...) must be respected, has described in Fig. 12 page 13.
• If there are highly flammable objects (curtains, fitted carpet, etc...), all these distances must be further
increased with 1 meter.
• If the walls are made up of flammable materials, check the safety distances (see Fig. 12 page 13).
• At maximum power check that the wall temperature does not ever exceed 80°C. If it would be necessary
please install a fire resistant plate on the concerned walls.
• In some countries also masonring load-bearing walls are considered flammable.
10.4
PANELS ASSEMBLY (VENUS PLUS MODEL)
Assembly must be carried out by an authorised technician.
For panels installation, proceed as follows:
VENUS PLUS - GIOIA-2
LEGEND
Fig. 11 page 12
5
28,5 cm
6
15 cm
7
7,5 cm
8
99,6 cm
9
35,1 cm
10
Hole combustion air inlet d.6 cm
11
Exhaust fumes d.8 cm
12
Hot air outlet d.8 cm
Fig. 12 - General installation
LEGEND
Fig. 12 page 13
1
Stove
2
Minimum lateral distance = 300 mm
3
Minimum rear distance = 300 mm
4
Minimum front distance = 1000 mm
EN
13