11.5
START UP
We remind you that the first ignition must be carried out by a specialized and authorixed technician who will
check that all is installed in compliance with current regulations and checks the efficiency.
EN
• If inside the combustion chamber there are booklets, manuals, etc..., remove them.
• Check if the door is correctly closed.
• Check if the stove is correctly inserted in the electric socket.
• Before switching the stove on, assure you the burning pot is clean.
• To start the stove up, keep pressed P4 key for an instant till it will be shown "START" and "PREHEAT WAIT": the
preheating of the ingnition resistance starts. After 2 minutes about, it will be shown "PELLET LOAD, WAITING FIRE",
in this phase the auger loads the pellet and the heating of the resistance continues. When the temperature is
sufficiently high (after 7-10 minutes about), the ignition is considered as happened and on the display shows
"FIRE PRESENT".
• Completed the phase "FIRE PRESENT", the control unit enter the "WORK" phase showing the set calorific
power and ambient temperature. It is in this phase that P5 and P6 keys settle the stove power from 1 to 5. If
the value of the ambient temperature exceeds the limit set on the keyboard on the temperature setting, the
calorific power will be carried at the minimum showing "WORK, MODULAT". When the ambient temperature
turns back below the set temperatur, the stove turns back to the set power.
11.6
STOVE ADJUSTMENT
The stove is adjusted according to the chimney flue and used pellets datas, as per technical characteristics (see
FEATURES page 38). If the datas do not correspond, the authorized technician can adjust the stove.
• If the pellet is small in size and with a greater calorific power, (for example: encrusted burning pot), the pellet
drop must be decreased from the menu "FLAME SETTING", press P3 "PELLET TYPE", press P3 again "PELLET
LOAD" and with P2 key decrease the pellet quantity from -1 (which is -2%) till -9 (which is -18%).
• If the chimney flue has a lower draught (for example: weak flame, sooty glass) the revolutions of the geared
motor must be increased from the menu "FLAME SETTING", press P5 "CHIMNEY TYPE", press P3 "FUME-EXT,
CHIMNEY" and with P1 key increase the fume fan revolutions from +1 (which is +5%) till +9 (which is +30%).
• If the chimney flue has a greater draught (for example: because of pellets fall on the burning pot) decrease
the fume fan revolutions from -1 to -9.
11.7
FAILED IGNITION
If the pellets do not burn, the failed ignition will be indicated by the alarm "FAILED IGNITION".
• If the room temperature is lower than 10°C, the plug is not able to bear the ignition stage. To support it please
insert some pellets in the burning pot and a piece of burning firelighter igniter material on the pellets (for
example firelighters cubes).
• Too much pellets in the burning pot, or humid pellet, or sooty burning pot make ignition difficult and create
dense white smoke which is harmful to health and can cause explosions on the combustion chamber. It is
therefore necessary not to stand in front of the stove during ignition stage if dense white smoke is present.
11.8
POWER FAILURE
• After a black-out lower than 5 seconds, the stove turns back to the power which was settled.
• After a black-out of more than 5 seconds, the stove enters the "COOLING WAIT" phase. Completed this
phase, it starts automatically up with the different phases (see START UP page 22).
11.9
TEMPERATURE SETTING
• To modify the ambient temperature it is sufficient to press P1 and P2 keys according to the desired temperature
inside the menu "SET TEMP ROOM".
• To see the set temperature, press once P1 key.
22
Pay attention if the value is positive or negative..
After a failed ignition the burning pot must be empty from the amassed pellets, before
starting the stove up again.
If after some months the flame appears weak and/or orange colored or the glass tends
to blackens and the burning pot to become encrusted, clean the stove, clean the fume
conduit and the chimney flue.
VENUS PLUS - GIOIA-2