ALARM
CAUSE
EN
Obstructed exhaust
Faulty exhaust fan
Obstructed outlet
connector
AL 8 - FAILURE
DEPRESS
Faulty pressostat
Faulty mother board
Extreme chimney lenght
Adverse weather
conditions
The fire door is not
correctly closed
AL 9 - DOOR
OPEN
Fire door microswitch
faulty or out of order
14.2
PROBLEM SOLVING
34
SOLUTION
The exhaust chimney is partially or tatally obstructed.
Please contact a Specialized Stove-repairer who checks
the stove exhaust up to the chimney pot. Please have it
immediately cleaned. It can be harmful to health to run
the stove with the obstructed chimney.
The pellets can burn also thank to chimney flue depression
without the aid of the exhaust fan. Have the exhaust fan
immediately replaced. It can be harmful to health to run
the stove without exhaust fan.
Clean the outlet connector.
Clean the pressostat.
Replace the mother board.
Contact a Specialized Stove-repairer and check that the
exhaust chimney is in accordance with the regulations:
see CHIMNEY FLUE page 5.
In case of strong wind there can be a negative pressure
to the chimney. Check it and start the stove up again.
Close the fire door correctly and check if the gaskets
are damaged. (In this case have it replaced by an
Authorized Technician).
Replace the fire door microswitch.
Before of every testing and/or intervention of the Authorized Technician, the Autorized
Technician personally has the duty to verify that the parameters of the electronic board
meet those of the reference table you own.
In case of doubts regarding the running of the stove please contact ONLY the Autorized
Technician in order to avoid irreparable damages!
INTERVENTION
VENUS PLUS - GIOIA-2