• It is forbidden to connect any other appliance (wood stoves, cooker hoods, boilers, etc...).
• The fume conduit must be placed at a distance of minimum 500 mm from flammable or heat-susceptible
components.
EN
8.10

EXAMPLES OF CORRECT INSTALLATION

• Chimney flue installation Ø120 mm with an enlarged drilling for pipe transit.
10
Fig. 8 - Example 1
LEGEND
Fig. 8 page 10
1
Insulating material
2
Reduction from Ø100 to Ø80 mm
3
Inspection plug
4
Minimum safety distance = 0,5 mt
Fig. 9 - Example 2
LEGEND
Fig. 9 page 10
1
Insulating material
2
Inspection plug
3
Chimney inspection entrance
4
Minimum safety distance = 0,5 mt
5
Inclination ≥ 3°
6
Level section ≤ 1 mt
VENUS PLUS - GIOIA-2