13.4
FUME CHAMBER CLEANING
Every 4/8 weeks the fume chamber cleaning must be executed.
• Unscrew the 2 fume chamber closing zincate panel screw (see Fig. 47 page 28).
• Clean with a vacuum cleaner the ash which has accumulated on the inner (see Fig. 48 page 28).
• After the cleaning the opposite operation is to repeat checking the gasket efficiency and integrity: if necessary
provide for its replacement by an Authorized Technician.
13.5
FUME CONDUIT CLEANING
The exhaust system must be cleaned every month.
28
Fig. 46 - Hopper and auger cleaning
The hand rejector grid must not ever be removed fron its housing. Clean the hopper bottom
and the visible part of the auger exclusively as shown in the picture (see Fig. 46 page 28).
If the auger is blocked by a foreign object (for example: nails), and if it needs to be cleaned,
DO NOT remove the hand rejector and DO NOT touch the auger. Please contact the
Technical Assistance service.
The hand rejector can be removed exclusively by an authorized technician.
Fig. 47 - Fume chamber
Fig. 48 - Fume chamber cleaning
VENUS PLUS - GIOIA-2