Status
Planning/Installation
Manual_FX-RB218_Int24_rev1
Error descriptionPossible
The robot does not
leave the charging
station
When travelling along
the boundary wire for
the first time, the
robot's track is
abnormal or it turns in
some sections of its
path.
problemProblem
The charging station
LED lights up red.
The charging station
LED flashes green.
Incorrect installation of
the charging station
Excess cable is rolled up
under the docking
station.
Corrosion on the
charging contacts
Charging contacts on
the station do not
touch the charging
contacts of the robot
correctly.
The rain sensor is active
The function for
recognising the
boundary wire is faulty.
There may be external
interference signals in
the vicinity, e.g.
underground power
grids, high-performance
electrical devices, etc.
The nearest boundary
wire to your neighbour
should be laid at least 2
m away from yours.
46
solution
-Check the perimeter
wire for breaks.
-Robot not sufficiently
charged
- Continue charging the
robot until the indicator
lights up green.
The "In" arrow must
point in the direction of
the working area.
Shorten the boundary
wire to avoid contact
and thus interference.
Clean the charging
contacts with steel
wool
Check whether the
station has sunk / is still
on the scales.
Clean all metal contacts
with Spritus
Enclose this
interference area with
your boundary wire to
keep the robot away
from this area.
Adjust the boundary
wire so that the robot