If the wall on which the sensor is to be installed is made of highly
heat-absorbing material (e.g. concrete, brick, etc.), or of hardened
glass, the sensor may be installed in the ceiling at a distance from
the heater, according to Figure 5.
1
1
Figure 5: Sensor installation on ceiling on centreline of heater as
seen from the front and side
1.
300 mm
Positioning the heater - recess installation
To position the sauna heater in a recess:
1.
Position the heater at a safe distance from the fl oor, side
walls and interior fi ttings (see Figure 6).
2.
Position the sensor according the picture (see Figure 6).
2
1
1
5
3
Figure 6: Positioning the heater - recess installation
1.
Minimum distance from side wall: 350 mm
2.
Sensor position alt 1: 500-1500 mm from heater
3.
Sensor
4.
Max. 1000 mm
5.
Sensor position alt 2: 500-1500 mm from heater front
6.
Sensor position: 1500 mm from fl oor
7.
Minimum distance from ceiling:
Sense Commercial 10: 980 mm
Sense Commercial 16-20: 1180 mm
8.
Minimum distance from interior fi ttings: 400 mm
9.
Minimum ceiling height:
Sense Commercial 10: 1900 mm
Sense Commercial 16-20: 2100 mm
10. Minimum distance: 20 mm
11. Minimum distance from interior fi ttings: 200 mm
12. Distance from fl oor: 270 mm
Placement of the control panel
Where possible, placement of the control panel outside the sauna
room is recommended due to lower ambient temperatures.
The control panel may be placed inside a Tylö sauna room or a
self-built sauna room with correct ventilation which operates ac-
cording to Tylö-recommended ventilation (natural ventilation prin-
3
8
4
9
6
11
10
ciple). Read the sections titled, Positioning the intake vent and
Positioning the outlet vent in these instructions. The control panel
must always be placed outside the sauna cabin if these require-
ments are not met. If installing the control panel inside the sauna
cabin, it should be positioned with regard to safety distances and
installation height, see Fig 7.
WARNING! With incorrect ventilation, a control
panel fi tted inside the sauna cabin may be expo-
sed to excessive temperatures, which can cause
the control panel to become deformed or defecti-
ve. The ambient temperature around the control
panel should never exceed 80°C.
Figure 7: Safety distance / installation height, control panel Pure,
Elite
1.
Heater
2.
Control panel
Positioning the inlet vent
7
Install the inlet vent straight through the wall under the centreline
of the heater.
Vent size for a family sauna approx. 125 cm² (heater 10.7kW) for
larger saunas approx. 300 cm² (heater 16-20kW).
The air circulation from the door must concord with the hot air
circulation from the heater.
12
Figure 8: Positioning the air intake and exhaust vents
1.
Inlet vent position.
2.
Outlet vent position through the sauna wall.
3.
Outlet vent position through the cavity.
4.
Outlet vent position via duct.
4
1
3. Max. 800 mm
4. Min. 300 mm
1
3
2
3
2
4