1
Figure 2: Schematic diagram of installation for control panel
TS 30
1.
Sauna heater
2.
Control panel (placed outside the sauna)
3.
Sensor (not extendable)
1
Figure 3: Schematic diagram of installation for control panel
Pure, Elite
1.
Sauna heater
2.
Control panel
3.
Sensor (extendable)
4.
External on/off switch (option, door contact needed for func-
tion)
5.
Door contact (option)
6.
Relay box RB Commercial/RB Commercial Lite (placed outsi-
de the sauna)
Control panel positioning (TS-panel)
The TS-panels are thermally controlled and have a patented divi-
ded eff ect. These should be installed on the wall or fi tted into
the wall.
If fi tted into the wall, there must always be insulation behind the
control panel. Capillary tube length 1850 mm. Also available with
capillary tube length 5000 mm.
3
2
3
4 5
2
6
Positioning the heater - normal installation
DANGER! No more than one heater may be instal-
led in the same sauna cabin.
Position the sauna heater:
•
on the same wall as the door (or the side wall if very close
to the door wall). The heater may also be placed in a recess
(see Figure 6).
•
Position the heater at a safe distance from the fl oor, side
walls and interior fi ttings (see Figure 4).
Position the sensor according the picture (see Figure 4).
2
1
4
3
Figure 4: Positioning the heater - normal installation
1.
Minimum distance from side wall: 150 mm
2.
Sensor position alt 1: 500-1500 mm from heater
3.
Sensor
4.
Sensor position alt 2: 500-1500 mm from heater front
5.
Sensor position: 1500 mm from fl oor
6.
Minimum distance from ceiling:
Sense Commercial 10: 980 mm
Sense Commercial 16-20: 1180 mm
7.
Minimum distance from interior fi ttings: 400 mm
8.
Minimum ceiling height:
Sense Commercial 10: 1900 mm
Sense Commercial 16-20: 2100 mm
9.
Minimum distance: 20 mm
10. Minimum distance from interior fi ttings: 200 mm
11. Distance from fl oor: 270 mm
3
7
8
5
10
9
11
13
6