8
KOPPLINGSSCHEMA 200-230 V 3~
2
L L
L
A B C D
1 2
3
L1
L2 L3
Fig 19: Manöverpanel TS 30-012, TS 30-6
1. Bastuaggregat Sense Commercial 10
2. Manöverpanel TS 30-012, TS 30-6
2
G
L
L
L
U
V
W
N
A
B C D
1
2
3
1
2
3 4 5 6
L1
L2 L3
1
G
U V W
Z X Y
1 2 3
4 5 6
Fig 20: Manöverpanel Pure, Elite
1. Bastuaggregat Sense Commercial 10-16-20
2. Reläbox RB Commercial/RB Commercial Lite
2A. RB Commercial/RB Commercial Lite PCB
2B. RB Commercial Lite (max. 10.7 kW)
2C. RB Commercial
3. Manöverpanel Pure, Elite
4. Sensor
5. Belysning
6. Extern on/off -brytare (tillval, dörrkontakt krävs för funktion)
7. Dörrkontakt (tillval)
KOPPLINGSSCHEMA 400-440 V 3~
2
L L
L
A B C D
1 2
3
L1
L2 L3
Fig 21: Manöverpanel TS 30-012, TS 30-6
1. Bastuaggregat Sense Commercial 16
2. Manöverpanel TS 30-012, TS 30-6
U V
W
Z X
Y
1 2
3
4 5
6
2B
A
A A
A
1 2 3
4
*
200-
AUX0
240 V~
*
Max 10A
2C
A
A A
A B
Z
X
Y
1 2 3
4
1 2 3
*
200-
200-
AUX0
240 V~
240 V~
*
Max 10A
4
1
* Elite - max 30m
** Pure - max 100m
U V
W
Z X
Y
1 2
3
4 5
6
1
U V
W
Z X
Y
1 2
3
4 5
6
2B
I
I I
I
B B
1 2 3
4
*
200-
INFRA
240 V~
1.5 mm²
200-240 V~ Max 100W
2C
2C
B B
B
C
C C
C
G M H V 1 2 3
4
1 2 3
4
*
*
200-
AUX1
AUX2
240 V~
1.5 mm²
200-240 V~ Max 100W
6
3
2
RJ10 4P4C
3 x 1.5 mm²
RJ10 4P4C
* **
RJ10 4P4C
7 x TAB
4 x TAB
1
U V
W
Z X
Y
1 2
3
4 5
6
TAB
200-208 V 3~
kW Amp
mm²
10.7 31
10
4
7
6
2A
V V
B B
1
2
3 4
5
6
7
8
9
3
7
5
TAB
200-208 V 3~
kW Amp
RJ10 4P4C
10.7 31
16
46
20
58
TAB
400-440 V 3~
kW Amp
mm²
16
23
6
230 V 3~
Amp
mm²
27
10
230 V 3~
mm²
Amp
mm²
10
27
10
16
40
16
25
50
16